Kurien Abraham, Ganpule Arvind, Muthu V, Sabnis R B, Desai Mahesh
Department of Urology, Muljibhai Patel Urological Hospital, Nadiad, India.
J Endourol. 2009 Jan;23(1):17-19. doi: 10.1089/end.2008.0341.
The surface area of the stone from a radiographic image is one of the more suitable parameters defining stone bulk. The widely accepted method of measuring stone surface area is to count the number of square millimeters enclosed within a tracing of the stone outline on graph paper. This method is time consuming and cumbersome with potential for human error, especially when multiple measurements are needed. The purpose of this study was to evaluate the accuracy, efficiency, and reproducibility of a commercially available imaging program, Adobe Photoshop 7.0 for the measurement of stone surface area.
The instructions to calculate area using the software are simple and easy in a Windows-based format. The accuracy of the imaging software was estimated by measuring surface areas of shapes of known mathematical areas. The efficiency and reproducibility were then evaluated from radiographs of 20 persons with radiopaque upper-tract urinary stones. The surface areas of stone images were measured using both graph paper and imaging software. Measurements were repeated after 10 days to assess the reproducibility of the techniques. The time taken to measure the area by the two methods was also assessed separately.
The accuracy of the imaging software was estimated to be 98.7%. The correlation coefficient between the two methods was R(2) = 0.97. The mean percentage variation using the imaging software was 0.68%, while it was 6.36% with the graph paper. The mean time taken to measure using the image analyzer and graph paper was 1.9 +/- 0.8 minutes and 4.5 +/- 1.08 minutes, respectively (P < 0.001)
The imaging program is accurate, fast, and highly reproducible in estimating two-dimensional stone surface area from radiographs compared with manual measurements using graph paper.
通过X线影像测量结石的表面积是界定结石体积较为合适的参数之一。广泛采用的测量结石表面积的方法是计算在绘图纸上描绘的结石轮廓内所包含的平方毫米数。该方法既耗时又繁琐,且存在人为误差的可能性,尤其是在需要进行多次测量时。本研究的目的是评估一款商用成像软件Adobe Photoshop 7.0在测量结石表面积方面的准确性、效率和可重复性。
该软件基于Windows格式,计算面积的操作简单易懂。通过测量已知数学面积的形状的表面积来评估成像软件的准确性。然后从20例患有不透X线的上尿路结石患者的X线片评估其效率和可重复性。使用绘图纸和成像软件分别测量结石图像的表面积。10天后重复测量以评估这些技术的可重复性。还分别评估了两种方法测量面积所需的时间。
成像软件的准确性估计为98.7%。两种方法之间的相关系数为R² = 0.97。使用成像软件的平均百分比变化为0.68%,而使用绘图纸时为6.36%。使用图像分析仪和绘图纸测量的平均时间分别为1.9±0.8分钟和4.5±1.08分钟(P < 0.001)。
与使用绘图纸进行手动测量相比,该成像软件在通过X线片估计二维结石表面积方面准确、快速且具有高度可重复性。