子宫颈癌患者中磁共振成像(MR)与正电子发射断层显像/X线计算机体层成像(PET/CT)的逐节点相关性:扩散加权成像与基于T2加权成像(T2WI)大小标准的比较

Node-by-node correlation between MR and PET/CT in patients with uterine cervical cancer: diffusion-weighted imaging versus size-based criteria on T2WI.

作者信息

Choi Eugene K, Kim Jeong Kon, Choi Hyuck Jae, Park Seong Ho, Park Bum-Woo, Kim Namkug, Kim Jae Seung, Im Ki Chun, Cho Gyunggoo, Cho Kyoung-Sik

机构信息

Department of Radiology, Asan Medical Center, University of Ulsan, 388-1 Poongnap dong, Songpa-gu, Seoul, 138-736, Korea.

出版信息

Eur Radiol. 2009 Aug;19(8):2024-32. doi: 10.1007/s00330-009-1350-5. Epub 2009 Mar 11.

Abstract

The purpose of the study was to perform a node-by-node comparison of an ADC-based diagnosis and various size-based criteria on T2-weighted imaging (T2WI) with regard to their correlation with PET/CT findings in patients with uterine cervical cancer. In 163 patients with 339 pelvic lymph nodes (LNs) with short-axis diameter >5 mm, the minimum apparent diffusion coefficient (ADC), mean ADC, short- and long-axis diameters, and ratio of long- to short-axis diameters (L/S ratio) were compared in PET/CT-positive and -negative LNs. On PET/CT, 118 (35%) LNs in 58 patients were positive. The mean value of minimum and mean ADCs, short- and long-axis diameters, and L/S ratio were different in PET/CT-positive (0.6436 x 10(-3) mm(2)/s, 0.756 x 10(-3) mm(2)/s, 10.3 mm, 13.2 mm, 1.32, respectively) and PET/CT-negative LNs (0.8893 x 10(-3) mm(2)/s, 1.019 x 10(-3) mm(2)/s, 7.4 mm, 11.0 mm, 1.49, respectively) (P < 0.05). The Az value of the minimum ADC (0.864) was greater than those of mean ADC (0.836), short-axis diameter (0.764), long-axis diameter (0.640) and L/S ratio (0.652) (P < 0.05). The sensitivity and accuracy of the minimum ADC (86%, 82%) were greater than those of the short-axis diameter (55%, 74%), long-axis diameter (73%, 58%) and L/S ratio (52%, 66%) (P < 0.05). ADC showed superior correlation with PET/CT compared with conventional size-based criteria on T2WI.

摘要

本研究的目的是对基于表观扩散系数(ADC)的诊断与T2加权成像(T2WI)上各种基于大小的标准进行逐个淋巴结比较,以探讨它们与子宫颈癌患者PET/CT结果的相关性。在163例患者的339个短轴直径>5mm的盆腔淋巴结(LN)中,比较了PET/CT阳性和阴性LN的最小表观扩散系数(ADC)、平均ADC、短轴和长轴直径以及长轴与短轴直径之比(L/S比)。在PET/CT上,58例患者的118个(35%)LN呈阳性。PET/CT阳性LN(分别为0.6436×10⁻³mm²/s、0.756×10⁻³mm²/s、10.3mm、13.2mm、1.32)和PET/CT阴性LN(分别为0.8893×10⁻³mm²/s、1.019×10⁻³mm²/s, 7.4mm, 11.0mm, 1.49)的最小和平均ADC、短轴和长轴直径以及L/S比的平均值不同(P<0.05)。最小ADC的Az值(0.864)大于平均ADC(0.836)、短轴直径(0.764)、长轴直径(0.640)和L/S比(0.652)(P<0.05)。最小ADC的敏感性和准确性(86%,82%)高于短轴直径(55%,74%)、长轴直径(73%,58%)和L/S比(52%,66%)(P<0.05)。与T2WI上基于大小的传统标准相比,ADC与PET/CT的相关性更好。

文献AI研究员

20分钟写一篇综述,助力文献阅读效率提升50倍。

立即体验

用中文搜PubMed

大模型驱动的PubMed中文搜索引擎

马上搜索

文档翻译

学术文献翻译模型,支持多种主流文档格式。

立即体验