Suppr超能文献

Karyometry: correction algorithm for differences in staining.

作者信息

Bartels Peter H, Bartels Hubert G, Alberts David S

机构信息

College of Optical Sciences, University of Arizona, Tucson, Arizona, USA.

出版信息

Anal Quant Cytol Histol. 2009 Apr;31(2):63-73.

Abstract

OBJECTIVE

To describe an algorithm that allows the correction of differences in staining of histopathologic sections while preserving chromatin texture.

STUDY DESIGN

In order to preserve the texture of the nuclear chromatin in the corrected digital imagery, it is necessary to correct the images pixel for pixel. This is accomplished by mapping each pixel's value onto the cumulative frequency distribution of the data set to which the image belongs, to transfer to the cumulative frequency distribution of the data set serving as standard and to project the intersection down onto the pixel optical density scale for the corrected value.

RESULTS

Feature values in the corrected imagery, for the majority of features used in karyometry, are between < 1% and a few percent of the feature values in standard imagery. For some higher-order statistical features involving multiple pixels, sensitivity to a shift in the cumulative frequency distribution may exist, and a secondary small correction by a factor may be required.

CONCLUSION

The correction algorithm allows the elimination of the effects of small staining differences on karyometric analysis.

摘要

相似文献

1
Karyometry: correction algorithm for differences in staining.
Anal Quant Cytol Histol. 2009 Apr;31(2):63-73.
2
Digital karyometry in pancreatic adenocarcinoma.
Anal Quant Cytol Histol. 2003 Apr;25(2):108-14.
4
Methods in quantitative image analysis.
Histochem Cell Biol. 1996 May;105(5):333-55. doi: 10.1007/BF01463655.
8
Integrated local binary pattern texture features for classification of breast tissue imaged by optical coherence microscopy.
Med Image Anal. 2017 May;38:104-116. doi: 10.1016/j.media.2017.03.002. Epub 2017 Mar 8.
10
Non-small cell lung cancer: histopathologic correlates for texture parameters at CT.
Radiology. 2013 Jan;266(1):326-36. doi: 10.1148/radiol.12112428. Epub 2012 Nov 20.

本文引用的文献

1
Karyometry in the early detection and chemoprevention of intraepithelial lesions.
Eur J Cancer. 2005 Sep;41(13):1875-88. doi: 10.1016/j.ejca.2005.07.002.
3
Characterization of chromatin distribution in cell nuclei.
Cytometry. 1986 Sep;7(5):467-74. doi: 10.1002/cyto.990070513.

文献AI研究员

20分钟写一篇综述,助力文献阅读效率提升50倍。

立即体验

用中文搜PubMed

大模型驱动的PubMed中文搜索引擎

马上搜索

文档翻译

学术文献翻译模型,支持多种主流文档格式。

立即体验