在囊性纤维化患者和健康人群运动期间对SenseWear活动监测仪的评估。

Evaluation of the SenseWear activity monitor during exercise in cystic fibrosis and in health.

作者信息

Dwyer Tiffany Jane, Alison Jennifer Ailsey, McKeough Zoe Jane, Elkins Mark Russell, Bye Peter Thomas Patrick

机构信息

Discipline of Physiotherapy, University of Sydney, Sydney, Australia.

出版信息

Respir Med. 2009 Oct;103(10):1511-7. doi: 10.1016/j.rmed.2009.04.013. Epub 2009 May 23.

Abstract

OBJECTIVE

Determine the SenseWear Pro3 Armband (SWA) accuracy for estimating energy expenditure (EE) and step count during treadmill walking in cystic fibrosis (CF) compared to healthy adults.

HYPOTHESIS

SWA estimation of EE would be less accurate for CF, than for healthy subjects, due to interference with the SWA skin sensors caused by the high salt concentration in the sweat of CF subjects.

METHODS

17 CF (mean age 26 yr; FEV1 54% predicted) and 17 age-matched control subjects walked slightly faster than their comfortable pace on a treadmill for 20 min, whilst simultaneously wearing the SWA and breathing through an open-circuit indirect calorimetry (IC) system. Subjects' steps were manually counted.

RESULTS

Combined EE data from all subjects showed no significant difference in EE measured by IC (6.0+/-3.4 kcal min(-1)) compared to the SWA estimate (6.3+/-2.5 kcal min(-1)), however the SWA significantly overestimated EE at low exercise intensities and underestimated EE at high exercise intensities. Correlations between EE values, estimated by the SWA and measured by IC, were greater than 0.85 (p<0.001) for both the CF and control group. Standard multiple regression showed that diagnosis of CF independently predicted less than 0.1% of the difference between the IC measure of EE and the SWA estimate. The SWA recorded slightly but significantly fewer steps (113+/-12 steps min(-1)) than the manual count (119+/-9 steps min(-1)).

CONCLUSION

Diagnosis of CF had no significant negative impact on the accuracy of the SWA estimate of EE. The SWA provided a reasonably accurate estimate of EE and step count during treadmill walking.

摘要

目的

与健康成年人相比,确定SenseWear Pro3臂带(SWA)在估计囊性纤维化(CF)患者跑步机行走时的能量消耗(EE)和步数方面的准确性。

假设

由于CF患者汗液中高盐浓度对SWA皮肤传感器的干扰,SWA对CF患者EE的估计准确性低于健康受试者。

方法

17名CF患者(平均年龄26岁;预计第一秒用力呼气量为54%)和17名年龄匹配的对照受试者在跑步机上以略快于舒适步速的速度行走20分钟,同时佩戴SWA并通过开路间接量热法(IC)系统呼吸。手动计数受试者的步数。

结果

所有受试者的综合EE数据显示,IC测量的EE(6.0±3.4千卡·分钟-1)与SWA估计值(6.3±2.5千卡·分钟-1)相比无显著差异,然而,SWA在低运动强度下显著高估EE,在高运动强度下低估EE。CF组和对照组中,SWA估计的EE值与IC测量的EE值之间的相关性均大于0.85(p<0.001)。标准多元回归显示,CF诊断独立预测的IC测量的EE与SWA估计值之间的差异不到0.1%。SWA记录的步数(113±12步·分钟-1)略低于但显著低于手动计数(119±9步·分钟-1)。

结论

CF诊断对SWA估计EE的准确性没有显著负面影响。SWA在跑步机行走期间对EE和步数提供了合理准确的估计。