Suppr超能文献

脉搏血氧测定法在测量心率变异性指标方面的局限性。

Limitations of oximetry to measure heart rate variability measures.

作者信息

Lu Guohua, Yang Fang

机构信息

Department of Biomedical Engineering, Fourth Military Medical University, Xi'an, People's Republic of China.

出版信息

Cardiovasc Eng. 2009 Sep;9(3):119-25. doi: 10.1007/s10558-009-9082-3.

Abstract

Measuring heart rate variability (HRV) is widely used to assess autonomic nervous system function. It requires accurate measurement of the interval between successive heartbeats. This can be achieved from recording the electrocardiogram (ECG), which is non-invasive and widely available. However, methodological problems inherent in recording and analyzing ECG traces have motivated a search for alternative means of measuring the interval between successive heartbeats. Recording blood oxygenation pulsations (photoplethysmography-PPG) is also convenient, non-invasive and widely available, and has been suggested as an effective alternative to ECG to derive HRV. Moreover, it has been claimed that the pulse waveforms produced by oximetry may be more practicable than R-R intervals measured from the by ECG, especially for ambulatory recordings. We have therefore compared PPG with ECG recordings to measure HRV applying the same signal analysis techniques to PPG and ECG recordings made simultaneously. Comparison of 5 min recording epochs demonstrated a very high degree of correlation, in temporal, frequency domains and non-linear analysis, between HRV measures derived from the PPG and ECG. However, we found that the PPG signal is especially vulnerable to motion artifacts when compared to the ECG, preventing any HRV analysis at all in a significant minority of PPG recordings. Our results demonstrate that even though PPG provides accurate interpulse intervals to measure heart rate variability under ideal conditions, it is less reliable due to its vulnerability to motion artifacts. Therefore it is unlikely to prove a practical alternative to the ECG in ambulatory recordings or recordings made during other activities.

摘要

测量心率变异性(HRV)被广泛用于评估自主神经系统功能。它需要准确测量连续心跳之间的间隔。这可以通过记录心电图(ECG)来实现,心电图是非侵入性的且广泛可用。然而,记录和分析心电图轨迹中固有的方法学问题促使人们寻找测量连续心跳间隔的替代方法。记录血液氧合脉动(光电容积脉搏波描记法 - PPG)也很方便、非侵入性且广泛可用,并且已被建议作为从心电图推导HRV的有效替代方法。此外,有人声称,通过血氧测定法产生的脉搏波形可能比从心电图测量的R - R间期更实用,特别是对于动态记录。因此,我们将PPG与心电图记录进行了比较,对同时进行的PPG和心电图记录应用相同的信号分析技术来测量HRV。对5分钟记录时段的比较表明,在时域、频域和非线性分析中,从PPG和心电图得出的HRV测量值之间具有非常高的相关性。然而,我们发现与心电图相比,PPG信号特别容易受到运动伪影的影响,在相当一部分PPG记录中完全无法进行任何HRV分析。我们的结果表明,尽管在理想条件下PPG能提供准确的脉搏间期来测量心率变异性,但由于其易受运动伪影影响,可靠性较低。因此,在动态记录或其他活动期间进行的记录中,它不太可能成为心电图的实用替代方法。

文献检索

告别复杂PubMed语法,用中文像聊天一样搜索,搜遍4000万医学文献。AI智能推荐,让科研检索更轻松。

立即免费搜索

文件翻译

保留排版,准确专业,支持PDF/Word/PPT等文件格式,支持 12+语言互译。

免费翻译文档

深度研究

AI帮你快速写综述,25分钟生成高质量综述,智能提取关键信息,辅助科研写作。

立即免费体验