Holladay Jack T
Baylor College of Medicine, Houston, TX, USA.
J Refract Surg. 2009 Oct;25(10 Suppl):S958-62. doi: 10.3928/1081597X-20090915-11.
PURPOSETo review the topographic patterns associated with keratoconus suspects and provide criteria for keratoconus screening.
Case study using maps from the NIDEK OPD-Scan II and OPD Station to highlight patterns seen in keratoconic corneas.
Five criteria are listed for the detection of keratoconus: 1) apex of the cone is not centered at the 6-o'clock semi-meridian, 2) cone should appear round on the tangential map, 3) keratometry >45.00 diopters, 4) corneal thickness at the apex of the cone is approximately 30 microm thinner than the corresponding distance above the pupil center, and 5) topographic patterns are not symmetric.
Standard corneal topography maps and simple clinical evaluation criteria are fundamental to detect keratoconus suspects and keratoconus.
目的
回顾与圆锥角膜疑似病例相关的地形图模式,并提供圆锥角膜筛查标准。
采用NIDEK OPD-Scan II和OPD Station的地图进行案例研究,以突出圆锥角膜中所见的模式。
列出了检测圆锥角膜的五条标准:1)圆锥顶点不在6点钟半子午线处居中;2)在切线图上圆锥应呈圆形;3)角膜曲率计测量值>45.00屈光度;4)圆锥顶点处的角膜厚度比瞳孔中心上方相应距离处约薄30微米;5)地形图模式不对称。
标准角膜地形图和简单的临床评估标准对于检测圆锥角膜疑似病例和圆锥角膜至关重要。