Department of Ophthalmology, Uppsala University Hospital, Sweden.
Acta Ophthalmol. 2011 Mar;89(2):151-8. doi: 10.1111/j.1755-3768.2009.01680.x.
This study aimed to investigate normal values and interocular differences in retinal nerve fibre layer (RNFL) thickness, using optical coherence tomography (OCT) and Heidelberg retinal tomography (HRT), in 5-16-year-old children born at full-term with normal birthweights.
Fifty-six children with normal visual acuity and refraction were examined with Stratus OCT and HRT. Three examinations were performed in each eye. One eye in each child was randomized for analyses of normal values. Findings in 54 eyes were evaluated. Mean values of RNFL thickness were calculated. Coefficients of variance and intraclass correlations were calculated. The correlation between right and left eyes and the limits of difference were determined for both methods.
Mean RNFL thickness was 98.4 μm (standard deviation [SD] 7.88 μm) assessed with OCT and 213.0 μm (SD 54.0 μm) assessed with HRT. No correlations between age or gender and RNFL thickness were found. The coefficients of variance were 2.9% and 5.6% for OCT and HRT, respectively, and intraclass correlations were 0.85 and 0.88, respectively. The limits of difference between the two eyes ranged from -9 μm to 9 μm with OCT and from -109 μm to 87 μm with HRT.
Both OCT and HRT can be used in children aged 5-16 years, but OCT provides less variability in determinations of RNFL thickness, both in repeated examinations of the same eye and in comparisons between the two eyes. The present study provides values for normal RNFL thickness in healthy children which can be used to make comparisons with values in children with optic nerve diseases.
本研究旨在通过光学相干断层扫描(OCT)和海德堡视网膜断层扫描仪(HRT),研究足月出生、体重正常的 5-16 岁儿童的视网膜神经纤维层(RNFL)厚度的正常值和眼间差异。
对 56 名视力和屈光度正常的儿童进行 Stratus OCT 和 HRT 检查。每只眼进行 3 次检查。每只儿童的一只眼随机进行正常值分析。评估了 54 只眼的结果。计算了 RNFL 厚度的平均值。计算了变异系数和组内相关系数。确定了两种方法中右眼和左眼之间的相关性和差异限值。
OCT 评估的平均 RNFL 厚度为 98.4 μm(标准差 [SD] 7.88 μm),HRT 评估的平均 RNFL 厚度为 213.0 μm(SD 54.0 μm)。年龄或性别与 RNFL 厚度之间无相关性。OCT 和 HRT 的变异系数分别为 2.9%和 5.6%,组内相关系数分别为 0.85 和 0.88。OCT 两眼之间的差异限值范围为-9 μm 至 9 μm,HRT 为-109 μm 至 87 μm。