Suppr超能文献

泡沫硬化疗法:心脏和脑部监测

Foam sclerotherapy: cardiac and cerebral monitoring.

作者信息

Morrison N, Neuhardt D L

机构信息

Morrison Vein Institute, 8575 E. Princess Dr, Suite 223, Scottsdale, Arizona 85255, USA.

出版信息

Phlebology. 2009 Dec;24(6):252-9. doi: 10.1258/phleb.2009.009051.

Abstract

OBJECTIVES

To investigate and review collected and reported transcutaneous ultrasound, transthoracic echocardiography (TTE) and transcranial Doppler (TCD) data obtained during ultrasound-guided foam sclerotherapy (USGFS) of incompetent saphenous, tributary and perforating veins of the lower extremities.

METHODS

TTE and/or middle cerebral artery TCD were performed during USGFS. Ultrasound (US) findings and adverse events were recorded. Existing literature was reviewed.

RESULTS

Ultrasound detected emboli circulating in superficial, perforating, communicating and deep veins and into the central circulation. TTE detected bright echoes in the right heart after every injection and in the left heart in up to 65% of selected patients. TCD high-intensity transient signals (HITS) were detected in 14-42% of the patients. Incidence of HITS was higher than patient reports of adverse events. Incidence of HITS was independent of foam volumes injected.

CONCLUSION

Echogenic signals were detected in non-treated veins, in heart chambers and in the cerebral circulation by transcutaneous US, TTE and TCD. Pathological consequences of such findings remain to be investigated.

摘要

目的

调查并回顾在下肢大隐静脉、属支静脉和穿支静脉功能不全的超声引导下泡沫硬化治疗(USGFS)过程中收集和报告的经皮超声、经胸超声心动图(TTE)及经颅多普勒(TCD)数据。

方法

在USGFS过程中进行TTE和/或大脑中动脉TCD检查。记录超声(US)检查结果及不良事件。对现有文献进行回顾。

结果

超声检测到栓子在浅静脉、穿支静脉、交通静脉及深静脉中循环,并进入体循环。每次注射后TTE在右心检测到明亮回声,在多达65%的选定患者的左心也检测到明亮回声。14% - 42%的患者检测到TCD高强度瞬态信号(HITS)。HITS的发生率高于患者报告的不良事件发生率。HITS的发生率与注入的泡沫量无关。

结论

经皮超声、TTE和TCD在未治疗的静脉、心腔及脑循环中检测到了回声信号。这些发现的病理后果仍有待研究。