Department of Restorative Dentistry, School of Dentistry of Ribeirão Preto, University of São Paulo, Ribeirão Preto, SP, Brazil.
Microsc Res Tech. 2011 Mar;74(3):281-6. doi: 10.1002/jemt.20902.
The purposes of this study were to evaluate in vitro the influence of different frequencies of Er:YAG laser on the human dentin caries removal capacity. Thirty fragments obtained from third molars were randomly assigned into three groups (n = 10) according to the laser frequency used: 4, 6, and 10 Hz. The caries lesion (±1 mm deep) was induced before the irradiation by S.mutans cultures for 6 weeks. The specimens of all groups were irradiated with 200 mJ of energy in noncontact and focused mode under constant refrigeration (water flow: 2.5 mL/min). Quantitative analysis of the caries removal was performed by DIAGNOdent™ and the Axion Vision™ software. Qualitative analysis was performed by Scanning electron microscope (SEM) and light microscope (LM). Data were analyzed by ANOVA and Fishers' tests. The DIAGNOdent™ revealed that the caries removal was similar with 4 and 6 Hz and was superior with 10 Hz (P < 0.05). The analysis with Axion Vision™ software revealed that the caries removal was similar with 6 and 10 Hz and the 4 Hz group promoted the lowest caries removal. Through SEM morphologic analysis, some specimens irradiated with 4 Hz presented, under the demineralized dentin, a disorganized collagenous matrix. The LM images revealed that all frequencies used promoted irregular caries removal, being observed over preparations with 6 and 10 Hz. It can be concluded that the increase of Er:YAG laser frequency provided a higher dentin caries removal without selectivity to the disorganized dentin.
本研究旨在评估不同频率的 Er:YAG 激光对人牙本质龋损去除能力的体外影响。将 30 个取自第三磨牙的碎片根据使用的激光频率随机分为三组(n = 10):4、6 和 10 Hz。通过 S.mutans 培养物诱导龋损(±1 mm 深)6 周后进行照射。所有组的标本均在非接触和聚焦模式下以 200 mJ 的能量进行照射,并在恒定的冷却下进行(水流:2.5 mL/min)。通过 DIAGNOdent™ 和 Axion Vision™ 软件对龋损去除进行定量分析。通过扫描电子显微镜(SEM)和光学显微镜(LM)进行定性分析。数据分析采用方差分析和 Fisher 检验。DIAGNOdent™ 显示,4 Hz 和 6 Hz 的龋损去除相似,而 10 Hz 的龋损去除更好(P < 0.05)。Axion Vision™ 软件分析显示,6 Hz 和 10 Hz 的龋损去除相似,而 4 Hz 组的龋损去除最低。通过 SEM 形态分析,一些用 4 Hz 照射的标本在脱矿牙本质下呈现出胶原基质紊乱。LM 图像显示,所有使用的频率都促进了不规则的龋损去除,在使用 6 和 10 Hz 的制备物上观察到了这种情况。可以得出结论,增加 Er:YAG 激光的频率提供了更高的牙本质龋损去除能力,而对紊乱的牙本质没有选择性。