Suppr超能文献

Er:YAG 激光频率对牙本质龋去除能力的影响。

Influence of Er:YAG laser frequency on dentin caries removal capacity.

机构信息

Department of Restorative Dentistry, School of Dentistry of Ribeirão Preto, University of São Paulo, Ribeirão Preto, SP, Brazil.

出版信息

Microsc Res Tech. 2011 Mar;74(3):281-6. doi: 10.1002/jemt.20902.

Abstract

The purposes of this study were to evaluate in vitro the influence of different frequencies of Er:YAG laser on the human dentin caries removal capacity. Thirty fragments obtained from third molars were randomly assigned into three groups (n = 10) according to the laser frequency used: 4, 6, and 10 Hz. The caries lesion (±1 mm deep) was induced before the irradiation by S.mutans cultures for 6 weeks. The specimens of all groups were irradiated with 200 mJ of energy in noncontact and focused mode under constant refrigeration (water flow: 2.5 mL/min). Quantitative analysis of the caries removal was performed by DIAGNOdent™ and the Axion Vision™ software. Qualitative analysis was performed by Scanning electron microscope (SEM) and light microscope (LM). Data were analyzed by ANOVA and Fishers' tests. The DIAGNOdent™ revealed that the caries removal was similar with 4 and 6 Hz and was superior with 10 Hz (P < 0.05). The analysis with Axion Vision™ software revealed that the caries removal was similar with 6 and 10 Hz and the 4 Hz group promoted the lowest caries removal. Through SEM morphologic analysis, some specimens irradiated with 4 Hz presented, under the demineralized dentin, a disorganized collagenous matrix. The LM images revealed that all frequencies used promoted irregular caries removal, being observed over preparations with 6 and 10 Hz. It can be concluded that the increase of Er:YAG laser frequency provided a higher dentin caries removal without selectivity to the disorganized dentin.

摘要

本研究旨在评估不同频率的 Er:YAG 激光对人牙本质龋损去除能力的体外影响。将 30 个取自第三磨牙的碎片根据使用的激光频率随机分为三组(n = 10):4、6 和 10 Hz。通过 S.mutans 培养物诱导龋损(±1 mm 深)6 周后进行照射。所有组的标本均在非接触和聚焦模式下以 200 mJ 的能量进行照射,并在恒定的冷却下进行(水流:2.5 mL/min)。通过 DIAGNOdent™ 和 Axion Vision™ 软件对龋损去除进行定量分析。通过扫描电子显微镜(SEM)和光学显微镜(LM)进行定性分析。数据分析采用方差分析和 Fisher 检验。DIAGNOdent™ 显示,4 Hz 和 6 Hz 的龋损去除相似,而 10 Hz 的龋损去除更好(P < 0.05)。Axion Vision™ 软件分析显示,6 Hz 和 10 Hz 的龋损去除相似,而 4 Hz 组的龋损去除最低。通过 SEM 形态分析,一些用 4 Hz 照射的标本在脱矿牙本质下呈现出胶原基质紊乱。LM 图像显示,所有使用的频率都促进了不规则的龋损去除,在使用 6 和 10 Hz 的制备物上观察到了这种情况。可以得出结论,增加 Er:YAG 激光的频率提供了更高的牙本质龋损去除能力,而对紊乱的牙本质没有选择性。

文献AI研究员

20分钟写一篇综述,助力文献阅读效率提升50倍。

立即体验

用中文搜PubMed

大模型驱动的PubMed中文搜索引擎

马上搜索

文档翻译

学术文献翻译模型,支持多种主流文档格式。

立即体验