To investigate the relationship between the peripapillary retinal nerve fiber layer (RNFL) thickness, as measured by Stratus time domain optical coherence tomography (OCT) (Stratus OCT) and Cirrus spectral domain OCT (Cirrus HD-OCT), and the severity indices of the visual field (VF) defects in glaucoma patients.
This was a prospective, cross-sectional study. Correlations between the individual VF sensitivity at 52 test points and the Stratus OCT and Cirrus HD-OCT, which determined peripapillary RNFL thicknesses from 6 sectors, were calculated in 54 eyes with open-angle glaucoma and 22 normal control eyes. The association between the RNFL thickness and VF sensitivity was evaluated using a second-order regression model.
A significant correlation was found for the RNFL thicknesses determined by the 2 OCT devices (r=0.51 to 0.95; P<0.001). VF sensitivities at each test point were also significantly correlated with the sectoral RNFL thicknesses. The inferotemporal RNFL sector exhibited the highest coefficient of determination, whereas the superotemporal test point had the highest VF sensitivity (Stratus, 0.70; Cirrus, 0.62).
The structure-function relationship was comparable between Cirrus HD-OCT and Stratus OCT RNFL measurements.
研究经 Stratus 时域光学相干断层扫描(Stratus OCT)和 Cirrus 频域光学相干断层扫描(Cirrus HD-OCT)测量的视盘周围视网膜神经纤维层(RNFL)厚度与青光眼患者视野(VF)缺损严重程度指数之间的关系。
这是一项前瞻性、横断面研究。对 54 只开角型青光眼眼和 22 只正常对照眼的 52 个测试点的个别 VF 敏感性与 Stratus OCT 和 Cirrus HD-OCT 之间的关系进行了计算,后者从 6 个扇区确定了视盘周围 RNFL 厚度。使用二阶回归模型评估 RNFL 厚度与 VF 敏感性之间的关联。
两种 OCT 设备确定的 RNFL 厚度之间存在显著相关性(r=0.51 至 0.95;P<0.001)。每个测试点的 VF 敏感性也与节段性 RNFL 厚度显著相关。下颞部 RNFL 扇区的决定系数最高,而上颞部测试点的 VF 敏感性最高(Stratus 为 0.70;Cirrus 为 0.62)。
Cirrus HD-OCT 和 Stratus OCT 的 RNFL 测量之间的结构-功能关系相当。