Kursaklioglu Hurkan, Barcin Cem, Iyisoy Atilla, Baysan Oben, Celik Turgay, Kose Sedat
Department of Cardiology, Gulhane Military Medical Academy, 06018 Ankara, Turkey.
Tex Heart Inst J. 2010;37(4):461-4.
The gold-standard treatment for prosthetic-valve paravalvular leakage is surgery to repair or replace the valve; however, the morbidity and mortality rates cannot be ignored, and some patients are poor surgical candidates. The percutaneous closure of such defects is possible, and different devices are being used for this purpose. In almost all instances, a femorofemoral or femorojugular wire loop is constructed to deliver the closure device. Herein, we present the case of a 61-year-old man in whom a mitral paravalvular leak was successfully closed with use of the Amplatzer Duct Occluder II, via retrograde approach under 3-dimensional transesophageal echocardiographic guidance, without the use of a wire loop. To the best of our knowledge, this is the 1st report of retrograde device deployment without the construction of an arteriovenous wire loop, and the 1st case in which the Amplatzer Duct Occluder II was used for the percutaneous closure of a mitral paravalvular leak.
人工瓣膜瓣周漏的金标准治疗方法是进行手术修复或置换瓣膜;然而,其发病率和死亡率不容忽视,而且一些患者并非手术的理想人选。经皮闭合此类缺损是可行的,目前正在使用不同的器械来实现这一目的。几乎在所有情况下,都需要构建股-股或股-颈钢丝环来输送闭合器械。在此,我们报告一例61岁男性患者,在三维经食管超声心动图引导下,通过逆行途径,成功使用Amplatzer动脉导管封堵器II闭合二尖瓣瓣周漏,且未使用钢丝环。据我们所知,这是首例未构建动静脉钢丝环而进行逆行器械置入的报告,也是首例使用Amplatzer动脉导管封堵器II经皮闭合二尖瓣瓣周漏的病例。