Suppr超能文献

基于钇(III)扰动向荧光法同步荧光测量药物制剂中的恩诺沙星及其在牛奶中的残留。

Synchronous fluorescence measurement of enrofloxacin in the pharmaceutical formulation and its residue in milks based on the yttrium (III)-perturbed luminescence.

机构信息

MOE Key Laboratory of Environmental Remediation and Ecological Health, College of Environmental and Resource Sciences, Zhejiang University, Hangzhou 310029, PR China.

出版信息

Talanta. 2010 Oct 15;82(5):1858-63. doi: 10.1016/j.talanta.2010.07.082. Epub 2010 Aug 8.

Abstract

A simple, rapid and sensitive synchronous fluorescence method is put forward for the determination of enrofloxacin (ENRO) in the pharmaceutical formulation and its residue in milk based on the yttrium (III)-perturbed luminescence. When Y(3+) is added into the ENRO solution, the fluorescence of ENRO is significantly enhanced. The synchronous fluorescence technology is employed in the method to determine trace amount of ENRO residue in milks. The synchronous fluorescence intensity of the system is measured in a 1-cm quartz cell with excitation wavelength of 328 nm, Δλ=80 nm. A good linear relationship between the fluorescence intensity and the ENRO concentration is obtained in the range of 1.0 × 10(-9) to 2.0 × 10(-6)mol L(-1) (r(2)=0.9992). The limit of detection (LOD) of this method attains as low as 3.0 × 10(-10) mol L(-1) (S/N=3). The selectivity of this method is also very good. Common metal ions, rare-earth ions and some pharmaceuticals, which are usually used together with ENRO, do not interfere with the determination of ENRO under the actual conditions. The proposed method can be applied to determine ENRO residue in milks, and limit of quantification (LOQ) determined in the spiked milk is estimated to be 2.8 × 10(-8) mol L(-1) (10 μg L(-1)). Moreover, this method can be used as a rapid screening for judging whether the ENRO residues in milks exceed Minimal Risk Levels (MRLs) or not. In addition, the mechanism of the fluorescence enhancement is also discussed in detail.

摘要

提出了一种基于钇(III)扰动向荧光法测定药物制剂和牛奶中恩诺沙星(ENRO)的简单、快速、灵敏的同步荧光法。当 Y(3+)加入到 ENRO 溶液中时,ENRO 的荧光显著增强。该方法采用同步荧光技术测定牛奶中痕量 ENRO 残留。在 1-cm 石英池中,以 328nm 为激发波长,Δλ=80nm,测定该体系的同步荧光强度。在 1.0×10(-9)至 2.0×10(-6)mol L(-1)范围内,荧光强度与 ENRO 浓度之间呈良好的线性关系(r(2)=0.9992)。该方法的检出限(LOD)低至 3.0×10(-10)mol L(-1)(S/N=3)。该方法的选择性也很好。在实际条件下,常见的金属离子、稀土离子和一些与 ENRO 一起使用的药物不会干扰 ENRO 的测定。该方法可用于测定牛奶中的 ENRO 残留,加标牛奶中确定的定量限(LOQ)估计为 2.8×10(-8)mol L(-1)(10μg L(-1))。此外,该方法可用于快速筛选判断牛奶中 ENRO 残留是否超过最低风险水平(MRL)。此外,还详细讨论了荧光增强的机理。

文献检索

告别复杂PubMed语法,用中文像聊天一样搜索,搜遍4000万医学文献。AI智能推荐,让科研检索更轻松。

立即免费搜索

文件翻译

保留排版,准确专业,支持PDF/Word/PPT等文件格式,支持 12+语言互译。

免费翻译文档

深度研究

AI帮你快速写综述,25分钟生成高质量综述,智能提取关键信息,辅助科研写作。

立即免费体验