Southern California Permanente Medical Group, San Diego, CA, USA.
J Shoulder Elbow Surg. 2011 Jan;20(1):33-8. doi: 10.1016/j.jse.2010.07.019. Epub 2010 Nov 4.
The biomechanical effects of placing a portal through the subscapularis tendon have not been studied. Our hypothesis is that placing a portal through the subscapularis tendon will affect the strain properties of the tendon.
Eight shoulders from deceased donors were dissected to expose the subscapularis musculotendinous unit. The subscapularis muscle was isolated, the arm was locked at neutral (0° abduction, 0° flexion/extension, 0° external rotation/internal rotation), and 3 cables were sutured to the subscapularis musculotendinous junction. Each cable was connected to a static weight. Three differential variable reluctance transducers (DVRTs) from Microstrain were sutured into the subscapularis tendon-superior, inferior, and in line with the proposed 5 o'clock portal. The musculotendinous unit was loaded along its line of action with 3, 9, and then 15 kg. Strain at each DVRT was measured in the native subscapularis tendon at each load level. The same strain measurement was taken after placing and removing a 5-mm suture anchor through the 5 o'clock portal and in the tendon after placing and removing an 8-mm cannula.
Penetrating the subscapularis tendon with either a 5-mm suture anchor or an 8-mm cannula does not produce any statistically significant change in strain compared with the native tendon.
Placing an anchor, or even an 8-mm cannulated portal, does not significantly alter the strain properties of the subscapularis tendon. This lack of effect on the strain characteristics of the subscapularis does not preclude the possibility of clinical effects.
尚未研究通过肩胛下肌腱放置入路的生物力学影响。我们的假设是,通过肩胛下肌腱放置入路将影响肌腱的应变特性。
从已故供体中解剖了 8 个肩部以暴露肩胛下肌肌腱。将肩胛下肌分离,手臂锁定在中立位(0°外展、0°屈曲/伸展、0°外旋/内旋),将 3 根电缆缝合到肩胛下肌肌腱-肌腹连接处。每根电缆都连接到一个静态重物。将三个微应变差分可变磁阻传感器 (DVRT) 缝合到肩胛下肌腱-上、下和与拟议的 5 点钟入路线一致的位置。在其作用线上加载肌腹,分别施加 3、9 和 15 kg 的力。在每个负载水平下测量每个 DVRT 处的原始肩胛下肌腱的应变。在放置和移除 5 毫米缝线锚钉穿过 5 点钟入路以及放置和移除 8 毫米套管后,在肌腱处测量相同的应变测量值。
与原始肌腱相比,穿过肩胛下肌腱放置 5 毫米缝线锚钉或 8 毫米套管并不会导致应变产生任何统计学上的显著变化。
放置锚钉,甚至是 8 毫米的套管,不会显著改变肩胛下肌腱的应变特性。这种对肩胛下肌腱应变特性的影响不会排除临床影响的可能性。