Dipartimento lnnovazione, Settore 1NN-F1S, CRE ENEA Frascati, Italy.
J Xray Sci Technol. 1995 Jan 1;5(3):261-77. doi: 10.3233/XST-1995-5302.
We report the characterization of a soft x-ray plasma source generated by a long-pulse XeCl excimer laser system. The output energy is 4 J at a wavelength of 308 nm in a 100-ns pulse. The intensity of radiation on target is estimated to be 4 × 1012 W cm-2. X-ray emission spectra of the plasma have been recorded using a double focusing spatial resolution spectrometer with a spherical mica crystal. From these measurements, the plasma temperature and electron density have been estimated. Various applications of such a plasma source have been investigated. First images of whole intact living cells from our system, imaged using the technique of soft x-ray contact microscopy, utilizing x rays in the "water window" region (280-530 eV), are shown. The suitability of the source for other applications, for example, x-ray lithography and radiation damage studies, to living cells are discussed. Possible improvements to the x-ray source for the various applications are proposed.
我们报道了一种由长脉冲 XeCl 准分子激光系统产生的软 X 射线等离子体源的特性。该系统在 100ns 脉冲下输出波长为 308nm 的能量为 4J。目标上的辐射强度估计为 4×1012Wcm-2。使用具有球形云母晶体的双聚焦空间分辨率光谱仪记录了等离子体的 X 射线发射光谱。根据这些测量结果,估算了等离子体的温度和电子密度。研究了这种等离子体源的各种应用。利用软 X 射线接触显微镜技术,从我们的系统中拍摄了完整的、完整的活细胞的第一张图像,该技术利用了“水窗”区域(280-530eV)的 X 射线。讨论了该光源在其他应用,例如 X 射线光刻和活细胞辐射损伤研究中的适用性。针对各种应用,提出了对 X 射线源的改进方案。