Ghosn M G, Mashiatulla M, Mohamed M A, Syed S, Castro-Chavez F, Morrisett J D, Larin K V
Department of Biomedical Engineering, University of Houston, Houston, TX 77204, USA.
Biochim Biophys Acta. 2011 May;1810(5):555-60. doi: 10.1016/j.bbagen.2011.02.003. Epub 2011 Feb 21.
Stored vascular tissues are employed in biomedical research for studies in imaging, in biomechanics, and/or in assessing vessel diseases. In the present study, the stability of aortic tissue in phosphate buffer saline (PBS) at 4°C was monitored over a course of 10 days as determined by the rate of glucose permeation measured by optical coherence tomography (OCT) and validated by histology.
The initial mean permeability through fresh porcine aorta was (2.32 ± 0.46)× 10(-5)cm/s (n=5); after maintaining the tissue at 4°C for 10 days, the mean rate was (7.37 ± 0.41)× 10(-5)cm/s (n=4), an increase of nearly 300%. A z-test verified that a significant change in the permeability rate (p<0.05) had occurred after 4 days of 4°C storage. Histology was used to quantify changes in tissue pore area. The increase in average pore area paralleled the increase in permeability rate over 10 days.
These results suggest that (1) the structural integrity of aortic tissue at 4°C is retained for at least the first three days after resection and (2) OCT is a powerful technology well suited for evaluating tissue structural integrity over time.
Functional OCT imaging provides for a noninvasive and quantitative technique in determining the structural integrity of aortic tissue stored at 4°C. This modality may be used for assessing the efficacy of other preservation techniques.
储存的血管组织用于生物医学研究,以进行成像、生物力学研究和/或评估血管疾病。在本研究中,通过光学相干断层扫描(OCT)测量并经组织学验证的葡萄糖渗透速率,监测了4℃下磷酸盐缓冲盐水(PBS)中主动脉组织在10天内的稳定性。
新鲜猪主动脉的初始平均渗透率为(2.32±0.46)×10⁻⁵cm/s(n = 5);在4℃下将组织保存10天后,平均速率为(7.37±0.41)×10⁻⁵cm/s(n = 4),增加了近300%。z检验证实,在4℃储存4天后,渗透率发生了显著变化(p<0.05)。组织学用于量化组织孔隙面积的变化。在10天内,平均孔隙面积的增加与渗透率的增加平行。
这些结果表明,(1)主动脉组织在4℃下的结构完整性在切除后的至少前三天得以保留,(2)OCT是一种非常适合随时间评估组织结构完整性的强大技术。
功能性OCT成像提供了一种无创且定量的技术,用于确定4℃下储存的主动脉组织的结构完整性。这种方法可用于评估其他保存技术的效果。