Suppr超能文献

使用市售便携式临床分析仪和标准实验室仪器测量的板鳃亚纲动物血液中的血气、氧饱和度、pH值和乳酸值。

Blood gas, oxygen saturation, pH, and lactate values in elasmobranch blood measured with a commercially available portable clinical analyzer and standard laboratory instruments.

作者信息

Gallagher Austin J, Frick Lorenz H, Bushnell Peter G, Brill Richard W, Mandelman John W

机构信息

Three Seas Program, Marine Science Center, Northeastern University, 430 Nahant Road, Nahant, Massachusetts 01908, USA.

出版信息

J Aquat Anim Health. 2010 Dec;22(4):229-34. doi: 10.1577/H10-012.1.

Abstract

Blood gas, pH, and lactate data are often used to assess the physiological status and health of fish and can often be most valuable when blood samples are analyzed immediately after collection. Portable clinical analyzers allow these measurements to be made easily in the field. However, these instruments are designed for clinical use and thus process samples at 37 degrees C. A few studies have validated the use of portable clinical analyzers for assessing blood gases and acid-base profiles in teleosts, but equivalent data are not available for elasmobranchs. We therefore examined the relationship of blood gas, pH, and lactate values measured with an i-STAT portable clinical analyzer with those measured using standard laboratory blood gas (thermostatted to 25 degrees C) and lactate analyzers in samples taken from three species of carcharhiniform sharks. We found tight correlations (r2 > 0.90) between these methods for pH, pO2, pCO2, and lactate level values. We thus developed species-specific equations for converting blood values measured with an i-STAT portable clinical analyzer to those taken at 25 degrees C. Additional studies need to address a wider range of temperatures and elasmobranch species.

摘要

血气、pH值和乳酸数据常被用于评估鱼类的生理状态和健康状况,且在采集血样后立即进行分析时往往最具价值。便携式临床分析仪使这些测量能够在现场轻松完成。然而,这些仪器是为临床使用而设计的,因此在37摄氏度下处理样本。一些研究已经验证了便携式临床分析仪在评估硬骨鱼血气和酸碱状况方面的应用,但对于软骨鱼来说,尚无等效数据。因此,我们研究了使用i-STAT便携式临床分析仪测量的三种真鲨科鲨鱼样本的血气、pH值和乳酸值与使用标准实验室血气分析仪(恒温至25摄氏度)和乳酸分析仪测量的值之间的关系。我们发现这些方法在pH值、氧分压、二氧化碳分压和乳酸水平值之间存在紧密的相关性(r2 > 0.90)。因此,我们开发了物种特异性方程,用于将使用i-STAT便携式临床分析仪测量的血液值转换为在25摄氏度下测量的值。还需要进一步的研究来探讨更广泛的温度范围和软骨鱼物种。

文献AI研究员

20分钟写一篇综述,助力文献阅读效率提升50倍。

立即体验

用中文搜PubMed

大模型驱动的PubMed中文搜索引擎

马上搜索

文档翻译

学术文献翻译模型,支持多种主流文档格式。

立即体验