Department of Diagnostic Radiology, Faculty of Life Sciences, Kumamoto University, Kumamoto, Japan.
Jpn J Radiol. 2011 Jun;29(5):366-70. doi: 10.1007/s11604-010-0557-3. Epub 2011 Jun 30.
Lanthanum carbonate (LC) is used to treat hyperphosphatemia. The purpose of this study was to investigate the signal intensity (SI) of LC on magnetic resonance imaging (MRI) scans of phantoms.
LC tablets were thoroughly ground and mixed with distilled water or edible agar (0.05, 0.25, 0.5, and 2.5 mg/ml) in plastic bottles. Four intact tablets were placed in plastic bottles that did or did not contain distilled water or agar. Two radiologists consensually evaluated T1- and T2-weighted images (WIs) obtained with 1.5- and 3.0-T MRI systems for the SI of unground and ground tablets.
On T1- and T2WI, the SIs of the LC suspensions and the solvents alone were similar; the SIs of unground tablets alone and of the air were also similar. Unground tablets in phantoms filled with solvent exhibited lower SI than the solvent. Ground tablets in suspension were not visualized on MRI or computed tomography. These results remained unchanged regardless of differences in magnetic field strength or the solvent used.
Ground LC had no contrast enhancement effect on T1WI; on T2WI it did not affect the SI of the solvent. Unground LC tablets may be visualized as a "filling defect" on MRI.
碳酸镧(LC)用于治疗高磷血症。本研究旨在探讨 LC 在磁共振成像(MRI)扫描中对体模的信号强度(SI)的影响。
将 LC 片剂彻底粉碎并与蒸馏水或食用琼脂(0.05、0.25、0.5 和 2.5mg/ml)混合在塑料瓶中。将四个完整的片剂分别放在含有或不含有蒸馏水或琼脂的塑料瓶中。两名放射科医生对使用 1.5 和 3.0-T MRI 系统获得的 T1 和 T2 加权图像(WI)进行了一致性评估,以评估未粉碎和粉碎片剂的 SI。
在 T1 和 T2WI 上,LC 混悬液和溶剂的 SI 相似;未粉碎片剂的 SI 与空气的 SI 也相似。在充满溶剂的体模中,未粉碎片剂的 SI 比溶剂低。混悬液中的粉碎片剂在 MRI 或计算机断层扫描中不可见。这些结果在不同的磁场强度或使用的溶剂下均保持不变。
粉碎后的 LC 对 T1WI 没有增强对比效果;在 T2WI 上,它不会影响溶剂的 SI。未粉碎的 LC 片剂在 MRI 上可能显示为“充盈缺损”。