Peinado Alba, Lizana Angel, Vidal Josep, Iemmi Claudio, Campos Juan
Departamento de Física, Universitat Autònoma de Barcelona, Bellatera, Spain.
Appl Opt. 2011 Oct 1;50(28):5437-45. doi: 10.1364/AO.50.005437.
This work evidences the suitability of applying a single twisted nematic liquid-crystal (TN-LC) device to obtain dynamic polarimeters with high accuracy and repeatability. Different Stokes polarimeter setups based on a TN-LC device are optimized, leading to the minimization of the noise propagated from intensity measurements to the Stokes vector calculations. To this aim, we revise the influence of working out of normal incidence and of performing a double pass of the light beam through the LC device. In addition, because transmissive TN-LC devices act as elliptical retarders, an extra study is performed. It analyzes the influence of projecting the light exiting from the TN-LC device over elliptical states of polarization. Finally, diverse optimized polarimeters are experimentally implemented and validated by measuring different states of partially and fully polarized light. The analysis is conducted both for monochromatic (He-Ne laser) and LED light sources, proving the potential of polarimeters based on a single TN-LC device.
这项工作证明了应用单个扭曲向列型液晶(TN-LC)器件来获得具有高精度和可重复性的动态偏振计的适用性。基于TN-LC器件的不同斯托克斯偏振计设置得到了优化,从而将从强度测量传播到斯托克斯矢量计算的噪声降至最低。为此,我们研究了偏离正入射工作以及使光束两次通过LC器件的影响。此外,由于透射型TN-LC器件充当椭圆延迟器,因此进行了额外的研究。它分析了将从TN-LC器件出射的光投射到椭圆偏振态上的影响。最后,通过测量部分偏振光和完全偏振光的不同状态,实验实现并验证了多种优化的偏振计。对单色(氦氖激光)和LED光源都进行了分析,证明了基于单个TN-LC器件的偏振计的潜力。