Suppr超能文献

不同边缘设计氧化锆全瓷冠的疲劳和断裂阻力。

Fatigue and fracture resistance of zirconia crowns prepared with different finish line designs.

机构信息

Dental Biometrical Department, Alexandria University, Egypt Department of Material Science, ACTA, Amsterdam, The Netherlands.

出版信息

J Prosthodont. 2012 Jan;21(1):22-7. doi: 10.1111/j.1532-849X.2011.00787.x. Epub 2011 Oct 31.

Abstract

PURPOSE

The aim of this study was to evaluate the effect of finish line design on the fatigue, fracture resistance, and failure type of veneered zirconia restorations.

MATERIALS AND METHODS

A CAD/CAM system (Cercon) was used to prepare zirconia frameworks (0.5 mm thick) for a maxillary central incisor. Three finish line designs were evaluated: a complete narrow chamfer, a narrow chamfer with a lingual ledge, and a complete ledge. The prepared frameworks were veneered using a press-on ceramic (Ceram Press) and were cemented on the corresponding prepared teeth using a resin cement (Panavia F2.0). The cemented specimens were thermocycled, subjected to dynamic fatigue, and finally loaded till fracture. Fractured specimens were examined under a scanning electron microscope to assess fracture type. One-way ANOVA and Bonferroni post hoc tests were used to analyze the data (α= 0.05).

RESULTS

The finish line design did not have any significant statistical influence on the fracture resistance (F = 1.9, p= 0.346) or on the failure type of the tested specimens. Adjusted R squared value (R = 0.049) indicated a weak correlation between finish line design and fracture load of the tested specimens. All specimens failed due to cracking and fracture of the veneer ceramic. Meanwhile, the framework remained entirely intact. Three narrow chamfer finish line specimens demonstrated adhesive fracture of the veneer ceramic during dynamic fatigue testing, related to overextension of the veneer ceramic during the layering procedure.

CONCLUSION

Within the limitations of this study, the finish line design did not influence the fatigue or the fracture resistance of veneered zirconia crowns. Selection of any of the finish line designs should be based on the clinical condition of the restored tooth.

摘要

目的

本研究旨在评估边缘设计对饰面氧化锆修复体的疲劳、抗折强度和失效类型的影响。

材料与方法

使用 CAD/CAM 系统(Cercon)制备上颌中切牙的氧化锆基底。评估了三种边缘设计:全窄斜面、带舌侧小肩台的窄斜面和全肩台。用压瓷技术(Ceram Press)对制备好的基底进行饰面,并用树脂水门汀(Panavia F2.0)粘接到相应的预备牙上。将粘好的样本进行热循环、动态疲劳测试,最后直至断裂加载。用扫描电子显微镜检查断裂的样本,评估断裂类型。采用单因素方差分析和 Bonferroni 事后检验进行数据分析(α=0.05)。

结果

边缘设计对试件的抗折强度(F=1.9,p=0.346)或失效类型均无显著统计学影响。调整后的 R 平方值(R=0.049)表明边缘设计与测试样本的断裂载荷之间存在微弱的相关性。所有样本均因饰面陶瓷的开裂和断裂而失效,而基底保持完整。三个窄斜面边缘设计的样本在动态疲劳测试中表现出饰面陶瓷的黏附性断裂,这与在分层过程中饰面陶瓷的过度伸展有关。

结论

在本研究的限制范围内,边缘设计不会影响饰面氧化锆冠的疲劳或抗折强度。边缘设计的选择应基于修复牙的临床状况。