Suppr超能文献

截肢者专用袜子:袜子的股数与袜子厚度有怎样的关系?

Amputee socks: how does sock ply relate to sock thickness?

作者信息

Sanders Joan E, Cagle John C, Harrison Daniel S, Karchin Ari

机构信息

University of Washington, Seattle, Washington, WA 98195, USA.

出版信息

Prosthet Orthot Int. 2012 Mar;36(1):77-86. doi: 10.1177/0309364611431290. Epub 2012 Jan 6.

Abstract

BACKGROUND

The term 'sock ply' may be a source of confusion in prosthetics practice because there may not be a consistent relationship between sock ply and sock thickness.

OBJECTIVES

The purpose of this study was to characterize how sock ply related to sock thickness for different sock materials commonly used in limb prosthetics. We also evaluated how sock thickness changed under loading conditions experienced while wearing a lower limb prosthesis compared with unstressed conditions.

STUDY DESIGN

Experimental. Mechanical assessment.

METHODS

Seven sock materials of varying ply and sheaths were tested using a custom instrument. Sock thickness under eight different compressive stress conditions and two different biaxial in-plane tensile strain conditions were measured.

RESULTS

For socks woven from a single material, thickness under walking stance phase conditions averaged 0.7, 1.2 and 1.5 mm for 1, 3 and 5-ply, respectively. For socks woven from several materials, the corresponding results were 0.4, 0.7 and 0.8 mm, respectively. Sock ply did not sum, e.g. a 3-ply sock was not three times the thickness of a 1-ply sock.

CONCLUSIONS

Sock thickness and compressive stiffness are strongly dependent upon sock material, interface pressure, and in-plane biaxial strain.

摘要

背景

“袜子层数”这一术语在假肢实践中可能会造成混淆,因为袜子层数与袜子厚度之间可能不存在一致的关系。

目的

本研究的目的是描述在肢体假肢中常用的不同袜子材料的袜子层数与袜子厚度之间的关系。我们还评估了与无应力状态相比,穿着下肢假肢时在加载条件下袜子厚度如何变化。

研究设计

实验性。力学评估。

方法

使用定制仪器对七种不同层数和护套的袜子材料进行测试。测量了在八种不同压缩应力条件和两种不同平面双轴拉伸应变条件下的袜子厚度。

结果

对于由单一材料编织的袜子,在步行站立期条件下,1层、3层和5层袜子的厚度平均分别为0.7毫米、1.2毫米和1.5毫米。对于由几种材料编织的袜子,相应的结果分别为0.4毫米、0.7毫米和0.8毫米。袜子层数并非简单相加,例如,3层袜子的厚度并非1层袜子厚度的三倍。

结论

袜子厚度和压缩刚度强烈依赖于袜子材料、界面压力和平面双轴应变。

相似文献

1
Amputee socks: how does sock ply relate to sock thickness?
Prosthet Orthot Int. 2012 Mar;36(1):77-86. doi: 10.1177/0309364611431290. Epub 2012 Jan 6.
2
Amputee socks: thickness of multiple socks.
Prosthet Orthot Int. 2014 Oct;38(5):405-12. doi: 10.1177/0309364613506915. Epub 2013 Nov 15.
3
Amputee socks: Sock thickness changes with normal use.
Prosthet Orthot Int. 2016 Jun;40(3):329-35. doi: 10.1177/0309364614568412. Epub 2015 Mar 2.
4
Self-reported prosthetic sock use among persons with transtibial amputation.
Prosthet Orthot Int. 2014 Aug;38(4):321-31. doi: 10.1177/0309364613499064. Epub 2013 Aug 28.
5
How do sock ply changes affect residual-limb fluid volume in people with transtibial amputation?
J Rehabil Res Dev. 2012;49(2):241-56. doi: 10.1682/jrrd.2011.02.0022.
6
Device to monitor sock use in people using prosthetic limbs: technical report.
J Rehabil Res Dev. 2012;49(8):1229-38. doi: 10.1682/jrrd.2011.09.0169.
7
Effect of sock on biomechanical responses of foot during walking.
Clin Biomech (Bristol). 2006 Mar;21(3):314-21. doi: 10.1016/j.clinbiomech.2005.10.002. Epub 2005 Nov 18.
9
A Novel Method to Measure the Static Coefficient of Friction for Socks.
Sensors (Basel). 2022 Jul 25;22(15):5525. doi: 10.3390/s22155525.
10
The effects of prosthetic foot stiffness on transtibial amputee walking mechanics and balance control during turning.
Clin Biomech (Bristol). 2017 Nov;49:56-63. doi: 10.1016/j.clinbiomech.2017.08.003. Epub 2017 Aug 15.

引用本文的文献

1
Transfemoral Socket Fabrication Method Using Direct Casting: Outcomes Regarding Patient Satisfaction with Device and Services.
Can Prosthet Orthot J. 2020 Nov 23;3(2):34672. doi: 10.33137/cpoj.v3i2.34672. eCollection 2020.
2
Performance of an auto-adjusting prosthetic socket during walking with intermittent socket release.
J Rehabil Assist Technol Eng. 2022 Apr 28;9:20556683221093271. doi: 10.1177/20556683221093271. eCollection 2022 Jan-Dec.
4
Modeling the mechanics of elevated vacuum systems in prosthetic sockets.
Med Eng Phys. 2020 Oct;84:75-83. doi: 10.1016/j.medengphy.2020.07.019. Epub 2020 Jul 28.
5
Characterization of Prosthetic Liner Products for People with Transtibial Amputation.
J Prosthet Orthot. 2018 Oct;30(4):187-199. doi: 10.1097/JPO.0000000000000205.
7
A finite element model to assess transtibial prosthetic sockets with elastomeric liners.
Med Biol Eng Comput. 2018 Jul;56(7):1227-1240. doi: 10.1007/s11517-017-1758-z. Epub 2017 Dec 13.
8
Effects of socket size on metrics of socket fit in trans-tibial prosthesis users.
Med Eng Phys. 2017 Jun;44:32-43. doi: 10.1016/j.medengphy.2017.03.003. Epub 2017 Apr 1.
9
Development of Standardized Material Testing Protocols for Prosthetic Liners.
J Biomech Eng. 2017 Apr 1;139(4):0450011-04500112. doi: 10.1115/1.4035917.
10
Technical note: Computer-manufactured inserts for prosthetic sockets.
Med Eng Phys. 2016 Aug;38(8):801-6. doi: 10.1016/j.medengphy.2016.04.019. Epub 2016 May 17.

本文引用的文献

文献AI研究员

20分钟写一篇综述,助力文献阅读效率提升50倍。

立即体验

用中文搜PubMed

大模型驱动的PubMed中文搜索引擎

马上搜索

文档翻译

学术文献翻译模型,支持多种主流文档格式。

立即体验