Meissner U, Stahl Harald, Steinkellner D
MKS, Munich, Germany.
PDA J Pharm Sci Technol. 2011 Sep-Oct;65(5):481-5. doi: 10.5731/pdajpst.2011.00748.
As a small leakage from the silicone oil tubes in pharmaceutical freeze dryers may go undetected for several cycles, it provides a major threat to both product safety and the economic performance of such installations. A properly mounted mass spectrometer offers a non-invasive method of detecting the smallest amounts of silicone oil down to 1 ppm. Additionally the system will improve leak testing procedures and can also be used as a process analytical technology tool to improve process control.
Drugs, and in particular parenterals, need to have a very high level of purity. A production process such as freeze drying carries the inherent risk of contamination by process fluids. This should not happen during routine production, but in the event of a malfunction small amounts of these fluids may contaminate the drug product. The purpose of this paper is to introduce a method which is able to detect such malfunctions before they can develop into a risk for drug purity and ultimately patient safety.
由于制药冷冻干燥机中硅油管道的微小泄漏可能在几个循环中都未被发现,这对产品安全以及此类设备的经济性能都构成了重大威胁。正确安装的质谱仪提供了一种非侵入性方法,可检测低至百万分之一的最少量硅油。此外,该系统将改进泄漏测试程序,还可作为过程分析技术工具来改善过程控制。
药物,尤其是注射剂,需要具有非常高的纯度。冷冻干燥等生产过程存在被过程流体污染的固有风险。在常规生产期间不应发生这种情况,但如果发生故障,少量这些流体可能会污染药品。本文的目的是介绍一种能够在故障发展成为药品纯度风险并最终威胁患者安全之前检测到此类故障的方法。