Department of Chemistry and Key Laboratory of Analytical Sciences, College of Chemistry and Chemical Engineering, Xiamen University, Xiamen 361005, Fujian Province, China.
Talanta. 2012 May 30;94:58-64. doi: 10.1016/j.talanta.2012.02.046. Epub 2012 Mar 7.
A novel electrochemical biosensing device that integrates an immunochromatographic test strip and a screen-printed electrode (SPE) connected to a portable electrochemical analyzer was presented for rapid, sensitive, and quantitative detection of disease-related biomarker in human blood samples. The principle of the sensor is based on sandwich immunoreactions between a biomarker and a pair of its antibodies on the test strip, followed by highly sensitive square-wave voltammetry (SWV) detection. Horseradish peroxidase (HRP) was used as a signal reporter for electrochemical readout. Hepatitis B surface antigen (HBsAg) was employed as a model protein biomarker to demonstrate the analytical performance of the sensor in this study. Some critical parameters governing the performance of the sensor were investigated in detail. Under optimal conditions, this sensor was capable of detecting a minimum of 0.3 ng mL(-1) (S/N=3) HBsAg with a wide linear concentration range from 1 to 500 ng mL(-1). The sensor was further utilized to detect HBsAg spiked in human plasma with an average recovery of 91.3%. In comparison, a colorimetric immunochromatographic test strip assay (ITSA) was also conducted. The result shows that the SWV detection in the electrochemical sensor is much more sensitive for the quantitative determination of HBsAg than the colorimetric detection, indicating that such a sensor is a promising platform for rapid and sensitive point-of-care testing/screening of disease-related biomarkers in a large population.
一种新型电化学生物传感装置,将免疫层析测试条和连接到便携式电化学分析仪的丝网印刷电极(SPE)集成在一起,用于快速、灵敏、定量检测人血样中的疾病相关生物标志物。传感器的原理基于测试条上的生物标志物和一对其抗体之间的夹心免疫反应,随后进行高灵敏度的方波伏安法(SWV)检测。辣根过氧化物酶(HRP)被用作电化学读出的信号报告器。本研究选用乙型肝炎表面抗原(HBsAg)作为模型蛋白生物标志物来展示传感器的分析性能。详细研究了一些控制传感器性能的关键参数。在最佳条件下,该传感器能够检测到最小浓度为 0.3 ng mL(-1)(S/N=3)的 HBsAg,线性浓度范围从 1 到 500 ng mL(-1)。该传感器还用于检测人血浆中添加的 HBsAg,平均回收率为 91.3%。相比之下,还进行了比色免疫层析测试条测定(ITSA)。结果表明,SWV 检测在电化学传感器中对 HBsAg 的定量测定比比色检测更灵敏,表明该传感器是一种用于在大人群中快速灵敏地进行疾病相关生物标志物的即时检测/筛选的有前途的平台。