Suppr超能文献

种植体即刻负重早期愈合过程中的种植体稳定性发展。

Development of implant stability during early healing of immediately loaded implants.

机构信息

Department of Dentistry, Charles University in Prague, Faculty of Medicine in Hradec Kralove, Czech Republic.

出版信息

Int J Oral Maxillofac Implants. 2012 May-Jun;27(3):619-27.

Abstract

PURPOSE

To monitor the development of stability of immediately loaded implants during early healing.

MATERIALS AND METHODS

A total of 90 interforaminally placed implants with an alkali-treated surface were considered. The stability of each implant was examined at placement and 1, 2, 3, 4, 5, 6, 8, and 10 weeks after the surgery using resonance frequency analysis (RFA) and damping capacity measurement. The development of implant stability, focusing on the decrease in stability (as measured by implant stability quotient [ISQ]) and the interplay of primary (ISQ0) and secondary implant stability, was evaluated. The implants were divided into three groups based on primary stability: group L (ISQ0 < 68), group M (ISQ0 68 to72), and group H (ISQ0 > 72). Stability curves for each group were created and analyzed statistically. Implant stability measurement results gained with RFA and damping capacity were compared employing the Wilcoxon paired test, correlation coefficients, and regression analysis. The threshold for statistical significance was set at P < .05.

RESULTS

The most pronounced decrease in ISQ values occurred 1 week after implant placement (mean decrease of 2.2 ISQ). During the 10-week experiment, mean ISQ rose by 5.5 in group L and by 1.3 in group M and dropped by 1.8 in group H (P < .001). The coefficient of determination R2 = 0.06 showed a weak dependence of RFA on the damping capacity (P < .001).

CONCLUSIONS

Implants with low primary stability showed a significant increase in stability during healing. In contrast, implants with high primary stability lost some stability over time.

摘要

目的

监测即刻负载种植体在早期愈合过程中的稳定性发展。

材料和方法

共考虑了 90 个经碱处理表面的椎间放置种植体。使用共振频率分析(RFA)和阻尼能力测量,在放置时以及手术后 1、2、3、4、5、6、8 和 10 周时,检查每个种植体的稳定性。评估种植体稳定性的发展,重点关注稳定性的降低(通过种植体稳定性指数[ISQ]测量)和主要(ISQ0)和次要种植体稳定性的相互作用。根据主要稳定性将种植体分为三组:组 L(ISQ0 < 68)、组 M(ISQ0 68 至 72)和组 H(ISQ0 > 72)。为每个组创建稳定性曲线并进行统计学分析。使用 Wilcoxon 配对检验、相关系数和回归分析比较 RFA 和阻尼能力获得的种植体稳定性测量结果。统计显著性的阈值设定为 P <.05。

结果

ISQ 值最明显的下降发生在植入后 1 周(平均下降 2.2 ISQ)。在 10 周的实验中,组 L 的平均 ISQ 增加了 5.5,组 M 增加了 1.3,组 H 下降了 1.8(P <.001)。决定系数 R2 = 0.06 表明 RFA 对阻尼能力的依赖性较弱(P <.001)。

结论

具有低主要稳定性的种植体在愈合过程中表现出显著的稳定性增加。相比之下,具有高主要稳定性的种植体随着时间的推移会失去一些稳定性。

文献AI研究员

20分钟写一篇综述,助力文献阅读效率提升50倍。

立即体验

用中文搜PubMed

大模型驱动的PubMed中文搜索引擎

马上搜索

文档翻译

学术文献翻译模型,支持多种主流文档格式。

立即体验