成人疑似臂丛神经病变患者的超声诊断性能:一项多中心回顾性研究,以 MRI、手术发现和临床随访为参考标准。

Diagnostic performance of ultrasound in patients with suspected brachial plexus lesions in adults: a multicenter retrospective study with MRI, surgical findings and clinical follow-up as reference standard.

机构信息

Department of Human Anatomy, DIMES, Università di Genova, Genoa, Italy.

出版信息

Skeletal Radiol. 2013 Mar;42(3):371-6. doi: 10.1007/s00256-012-1471-9. Epub 2012 Jun 17.

Abstract

PURPOSE

To evaluate brachial plexus ultrasound (US) performance in a large multicenter study.

MATERIALS AND METHODS

The research was approved by the Institutional Review Boards, and all patients gave written informed consent. A multicenter retrospective trial including three centers was performed between March, 2006 and April, 2011. A total of 204 patients who received a brachial plexus ultrasound requested by the referring physician were enrolled: magnetic resonance imaging, surgical findings and clinical follow-up of at least 12 months were used as the reference standard. Sensitivity, specificity with 95 % confidence intervals (CIs), positive predictive value (PPV), pre-test-probability (the prevalence), negative predictive value (NPV), pre- and post- test odds (OR), likelihood ratio for positive results (LH+), likelihood ratio for negative results (LH-), accuracy and post-test probability (post-P) were reported on a per-patient basis.

RESULTS

The overall sensitivity and specificity with 95 % CIs were: 0.76 (0.75-0.97); 0.96 (0.77-0.89). Overall PPV, pre-test probability, NPV, pre-OR, post-OR, LH+, LH-, Accuracy and post-P were: 0.93/0.43/0.84/0.75/0.75/13.4/17.6/0.25/0.88/0.93, respectively.

CONCLUSIONS

The specificity of brachial plexus US in patients suspected of having a brachial plexus lesion is very high.

摘要

目的

在一项大型多中心研究中评估臂丛神经超声(US)的性能。

材料和方法

该研究经机构审查委员会批准,所有患者均签署了书面知情同意书。 2006 年 3 月至 2011 年 4 月进行了一项包括三个中心的多中心回顾性试验。共纳入 204 例因主治医生要求接受臂丛神经超声检查的患者:将磁共振成像、手术发现和至少 12 个月的临床随访作为参考标准。基于每位患者报告灵敏度、特异度及 95%置信区间(CI)、阳性预测值(PPV)、预测试概率(患病率)、阴性预测值(NPV)、前后测试比值(OR)、阳性结果似然比(LH+)、阴性结果似然比(LH-)、准确率和后测试概率(post-P)。

结果

总体灵敏度和特异度的 95%CI 分别为:0.76(0.75-0.97)和 0.96(0.77-0.89)。总体 PPV、预测试概率、NPV、预 OR、后 OR、LH+、LH-、准确率和后测试概率分别为:0.93/0.43/0.84/0.75/0.75/13.4/17.6/0.25/0.88/0.93。

结论

怀疑臂丛神经病变患者的臂丛神经 US 特异性非常高。