Department of Analytical Chemistry, Campus of Rabanales, University of Córdoba, E-14071 Córdoba, Spain.
J Chromatogr A. 2012 Jul 27;1248:1-8. doi: 10.1016/j.chroma.2012.05.067. Epub 2012 May 31.
Halonitromethanes (HNMs) are a class of nitrogenous disinfection by-products (N-DBPs) that have so far received little attention and focused largely on trichloronitromethane. By contrast, trihalomethanes (THMs) are the most commonly regulated DBPs and have been the subject of much study. This paper reports the first miniaturized system for the simultaneous determination of the nine known HNMs and four THMs in tap and swimming pool water. Micro liquid-liquid extraction (MLLE) is an adaptation of EPA Method 551.1 using ethyl acetate instead of methyl tert-butyl ether as extractant and large injected sample volumes (30 μL) in combination with programmed temperature vaporizer-gas chromatography-mass spectrometry for improved sensitivity and selectivity. Because extraction is done with a few microlitres of organic solvent (200 μL) and practically all extract is injected into the instrument, MLLE can be regarded as a virtually solvent-free sample preparation technique. The proposed method provided an extraction efficiency of ∼85%, average limits of detection (tribromonitromethane excluded) of 30 ng/L and relative standard deviations of ∼6.0%. The influence of various dechlorinating agents on the stability of the thirteen target analytes in treated water was evaluated; the only salt allowing both types of compounds to be efficiently preserved was (NH(4))(2)SO(4), but only for 1 day at 4 °C. Therefore, acidifying the sample at pH ∼3.4-the optimum value for MLLE-at the time of collection is recommended in order to ensure that both HNMs and THMs retain their integrity for 2 days during storage at 4 °C.
卤代硝基甲烷(HNMs)是一类含氮消毒副产物(N-DBPs),目前受到的关注较少,主要集中在三氯硝基甲烷上。相比之下,三卤甲烷(THMs)是最常见的受管制的 DBPs,已经进行了大量研究。本文报道了首个用于同时测定自来水中和游泳池水中的 9 种已知 HNMs 和 4 种 THMs 的微型化系统。微型液液萃取(MLLE)是 EPA 方法 551.1 的一种改编,使用乙酸乙酯代替甲基叔丁基醚作为萃取剂,并采用大进样量(30 μL)和程序升温汽化-气相色谱-质谱联用,以提高灵敏度和选择性。由于萃取仅使用数微升有机溶剂(200 μL),并且几乎所有萃取物都注入仪器中,因此 MLLE 可以被视为一种实质上无溶剂的样品制备技术。所提出的方法提供了约 85%的萃取效率,(排除三溴硝基甲烷)平均检测限为 30 ng/L,相对标准偏差约为 6.0%。评估了各种脱氯剂对处理水中 13 种目标分析物稳定性的影响;仅有一种盐((NH4)2SO4)允许两种化合物都被有效地保存,但仅在 4 °C 下保存 1 天。因此,建议在收集时将样品酸化至 pH ∼3.4(MLLE 的最佳值),以确保在 4 °C 下储存期间,HNMs 和 THMs 都能保持完整状态达 2 天。