Department of Physical Education and Sports, Institute of Biomedicine (IBIOMED), University of León, León, Spain.
J Strength Cond Res. 2013 Apr;27(4):1162-7. doi: 10.1519/JSC.0b013e31826520d7.
The purposes of this study were to analyze the validity and reliability of 2 photocell mats and to probe the possible influence of the type of mat (contact vs. photocell) on vertical jump height estimated from flight time. In 2 separate studies, 89 and 92 physical students performed 3 countermovement jumps that were simultaneously registered by a Force Plate (gold standard method), 2 photocell mats (SportJump System Pro and ErgoJump Plus), and a contact mat (SportJump-v1.0). The first study showed that the 2 photocell mats underestimated the vertical jump height (1.3 ± 0.2 cm and 5.9 ± 5.2 cm, respectively), but only SportJump System Pro showed a high correlation with the Force Plate (r = 0.999 and 0.676, respectively) and good intraday reliability (coefficient of variation = 2.98 and 15.94%, intraclass correlation coefficients = 0.95-0.97 and 0.45-0.57, respectively). The second study demonstrated a strong correlation (r = 0.994) between the 2 technologies (contact vs. photocell mats) with differences in vertical jump height of 2.0 ± 0.8 cm (95% confidence interval = 1.9-2.1 cm), which depended on both flight time and subjects' body mass. In conclusion, SportJump System Pro was a valid and reliable device. The new devices to measure vertical jump height from flight time should be validated. The type of mat (contact vs. photocell) affected approximately 6% the vertical jump height (approximately 2 cm in this study), which should be considered in further studies. The use of validated photocell mats instead of the contact mats was recommended.
本研究旨在分析两种光电传感器垫的有效性和可靠性,并探讨其对基于飞行时间估计的垂直跳跃高度的可能影响。在两项独立的研究中,89 名和 92 名体育学生分别完成了 3 次反跳,同时由力板(金标准方法)、2 个光电传感器垫(SportJump System Pro 和 ErgoJump Plus)和一个接触垫(SportJump-v1.0)记录。第一项研究表明,两种光电传感器垫均低估了垂直跳跃高度(分别为 1.3 ± 0.2 cm 和 5.9 ± 5.2 cm),但只有 SportJump System Pro 与力板高度相关(r 值分别为 0.999 和 0.676),日内重复性好(变异系数分别为 2.98%和 15.94%,组内相关系数分别为 0.95-0.97 和 0.45-0.57)。第二项研究表明,两种技术(接触垫与光电垫)之间具有很强的相关性(r = 0.994),垂直跳跃高度差异为 2.0 ± 0.8 cm(95%置信区间为 1.9-2.1 cm),这取决于飞行时间和受试者的体重。综上所述,SportJump System Pro 是一种有效且可靠的设备。应验证新的基于飞行时间测量垂直跳跃高度的设备。垫的类型(接触垫与光电垫)会影响约 6%的垂直跳跃高度(在本研究中约为 2 cm),在进一步的研究中应予以考虑。建议使用经过验证的光电传感器垫代替接触垫。