Suppr超能文献

垫子的类型(接触式与光电式)会影响根据飞行时间估算的垂直跳跃高度。

The type of mat (Contact vs. Photocell) affects vertical jump height estimated from flight time.

机构信息

Department of Physical Education and Sports, Institute of Biomedicine (IBIOMED), University of León, León, Spain.

出版信息

J Strength Cond Res. 2013 Apr;27(4):1162-7. doi: 10.1519/JSC.0b013e31826520d7.

Abstract

The purposes of this study were to analyze the validity and reliability of 2 photocell mats and to probe the possible influence of the type of mat (contact vs. photocell) on vertical jump height estimated from flight time. In 2 separate studies, 89 and 92 physical students performed 3 countermovement jumps that were simultaneously registered by a Force Plate (gold standard method), 2 photocell mats (SportJump System Pro and ErgoJump Plus), and a contact mat (SportJump-v1.0). The first study showed that the 2 photocell mats underestimated the vertical jump height (1.3 ± 0.2 cm and 5.9 ± 5.2 cm, respectively), but only SportJump System Pro showed a high correlation with the Force Plate (r = 0.999 and 0.676, respectively) and good intraday reliability (coefficient of variation = 2.98 and 15.94%, intraclass correlation coefficients = 0.95-0.97 and 0.45-0.57, respectively). The second study demonstrated a strong correlation (r = 0.994) between the 2 technologies (contact vs. photocell mats) with differences in vertical jump height of 2.0 ± 0.8 cm (95% confidence interval = 1.9-2.1 cm), which depended on both flight time and subjects' body mass. In conclusion, SportJump System Pro was a valid and reliable device. The new devices to measure vertical jump height from flight time should be validated. The type of mat (contact vs. photocell) affected approximately 6% the vertical jump height (approximately 2 cm in this study), which should be considered in further studies. The use of validated photocell mats instead of the contact mats was recommended.

摘要

本研究旨在分析两种光电传感器垫的有效性和可靠性,并探讨其对基于飞行时间估计的垂直跳跃高度的可能影响。在两项独立的研究中,89 名和 92 名体育学生分别完成了 3 次反跳,同时由力板(金标准方法)、2 个光电传感器垫(SportJump System Pro 和 ErgoJump Plus)和一个接触垫(SportJump-v1.0)记录。第一项研究表明,两种光电传感器垫均低估了垂直跳跃高度(分别为 1.3 ± 0.2 cm 和 5.9 ± 5.2 cm),但只有 SportJump System Pro 与力板高度相关(r 值分别为 0.999 和 0.676),日内重复性好(变异系数分别为 2.98%和 15.94%,组内相关系数分别为 0.95-0.97 和 0.45-0.57)。第二项研究表明,两种技术(接触垫与光电垫)之间具有很强的相关性(r = 0.994),垂直跳跃高度差异为 2.0 ± 0.8 cm(95%置信区间为 1.9-2.1 cm),这取决于飞行时间和受试者的体重。综上所述,SportJump System Pro 是一种有效且可靠的设备。应验证新的基于飞行时间测量垂直跳跃高度的设备。垫的类型(接触垫与光电垫)会影响约 6%的垂直跳跃高度(在本研究中约为 2 cm),在进一步的研究中应予以考虑。建议使用经过验证的光电传感器垫代替接触垫。

文献AI研究员

20分钟写一篇综述,助力文献阅读效率提升50倍。

立即体验

用中文搜PubMed

大模型驱动的PubMed中文搜索引擎

马上搜索

文档翻译

学术文献翻译模型,支持多种主流文档格式。

立即体验