咽鼓管在患者咽鼓管异常开放症时的运动:使用 320 排容积 CT 扫描仪的评估。

Movement of the Eustachian tube during sniffing in patients with patulous Eustachian tube: evaluation using a 320-row area detector CT scanner.

机构信息

Departments of Otolaryngology, Fujita Health University School of Medicine, Toyoake Aichi, Japan.

出版信息

Otol Neurotol. 2013 Jul;34(5):877-83. doi: 10.1097/MAO.0b013e31827d0963.

Abstract

OBJECTIVE

The Eustachian tube is difficult to evaluate because it is located deep in the head. However, the introduction of 320-row area detector CT has made it possible to evaluate this region. In the present study, movement of the Eustachian tube during sniffing was visualized using area detector CT in patients with patulous Eustachian tube.

METHODS

Four patients with patulous Eustachian tube were examined using an area detector CT scanner (Aquilion ONE, Toshiba). This scanner supports 320-row scanning of 0.5-mm slices at up to 0.275 s/rot., eliminating temporal mismatch between various parts of the acquired images and permitting 4-dimensional CT (4DCT) images to be obtained by continuous scanning. The scan conditions were 120 kV, 120 to 150 mA, 0.5 mm × 280 to 320 slices, and 0.35 seconds per rotation × 9 rotations. The patient was seated on a reclining chair tilted to 45 degrees and was instructed to sniff during continuous scanning. Images of the Eustachian tube were generated at 0.1-second intervals.

CONCLUSION

At the start of sniffing, the cartilaginous portion of the Eustachian tube closed from the isthmus toward the pharynx. The starting point differed from patient to patient. In patients with patulous Eustachian tube, sniffing (an unconscious habit that helps to relieve ear discomfort) is an important factor in the development of middle ear diseases. We have successfully depicted this event for the first time, demonstrating various patterns of Eustachian tube closure during sniffing in patients with patulous Eustachian tube. This method may be useful for evaluating Eustachian tube dysfunction.

摘要

目的

咽鼓管位置深在,评估较为困难。但随着 320 排容积 CT 的出现,使得对咽鼓管的评估成为可能。本研究旨在利用容积 CT 对咽鼓管异常开放患者行吞咽动作时咽鼓管的运动进行评估。

方法

4 例咽鼓管异常开放患者,使用容积 CT 扫描仪(Aquilion ONE,东芝公司)进行检查。该扫描仪支持 0.5mm 层厚、320 排扫描,扫描速度可达 0.275s/转,可消除采集图像不同部位间的时间失配,实现连续扫描的 4 维 CT(4DCT)。扫描条件:120kV,120150mA,0.5mm×280320 层,0.35s/转×9 转。患者坐在 45°倾斜的可调节椅上,于连续扫描过程中进行吞咽动作。以 0.1 秒为间隔获取咽鼓管图像。

结论

在吞咽开始时,咽鼓管软骨部从峡部向咽部关闭。但起始点因患者而异。在咽鼓管异常开放患者中,吞咽(一种有助于缓解耳部不适的无意识习惯)是中耳疾病发生的一个重要因素。我们首次成功描绘了这一事件,展示了咽鼓管异常开放患者吞咽时咽鼓管关闭的各种模式。该方法可能有助于评估咽鼓管功能障碍。