Antończyk Karolina, Paluszkiewicz Lech, Koertke Heinrich, Gummert Jan
Department of Thoracic and Cardiovascular Surgery, Heart and Cardiovascular Centre North Rhine-Westphalia, Ruhr University Bochum, Bad Oeynhausen, Germany.
Interact Cardiovasc Thorac Surg. 2013 Aug;17(2):428-30. doi: 10.1093/icvts/ivt174. Epub 2013 Apr 18.
In this case report, we present a patient 28 years after mitral valve replacement with the Starr-Edwards prosthesis complicated by periprosthetic leak with severe aortic stenosis and moderate tricuspid regurgitation. We successfully repaired the periprosthetic regurgitation in a patient with extensive mitral annular calcification, without replacement of the valve. No apparent structural deterioration on the caged-ball valve was found. Moreover, aortic valve replacement and tricuspid annuloplasty were performed. One month after reoperation, the patient remained stable with improved clinical status and without any evidence for further paravalvular leak.
在本病例报告中,我们介绍了一位在二尖瓣置换术后28年的患者,其所植入的Starr-Edwards人工瓣膜出现瓣周漏,并伴有严重主动脉瓣狭窄和中度三尖瓣反流。我们成功修复了一位存在广泛二尖瓣环钙化患者的瓣周反流,未进行瓣膜置换。未发现笼球瓣有明显的结构恶化。此外,还进行了主动脉瓣置换和三尖瓣环成形术。再次手术后一个月,患者病情保持稳定,临床状况改善,且无进一步瓣周漏的迹象。