Shimizu Tomoharu, Obata Toru, Sonoda Hiromichi, Akabori Hiroya, Tabata Takahisa, Eguchi Yutaka, Endo Yoshihiro, Tani Tohru
Department of Surgery, Shiga University of Medical Science, Otsu, Shiga, Japan.
Transfus Apher Sci. 2013 Dec;49(3):499-503. doi: 10.1016/j.transci.2013.04.042. Epub 2013 May 16.
The patients' hemodynamic conditions of septic shock due to intra-abdominal infection were improved by the longer duration of direct hemoperfusion with a polymyxin B-immobilized fiber column (PMX), reducing plasma endotoxins measured by the novel endotoxin detection method, named endotoxin scattering photometry (ESP) method; however, turbidimetric method could not detect endotoxins. We also observed the reduction in the endotoxin after passing through column by ESP method even after the longer duration of PMX. ESP method may more sensitively detect endotoxins than the ordinary turbidimetric method. Moreover, we demonstrated the ability of endotoxin adsorption in spite of the longer duration of PMX.