Suppr超能文献

成功地将体积减小的脐血单位在低温机械冷冻器中进行短期冷冻保存:对细胞回收率、活力和集落形成能力的影响。

Successful short-term cryopreservation of volume-reduced cord blood units in a cryogenic mechanical freezer: effects on cell recovery, viability, and clonogenic potential.

机构信息

Hellenic Cord Blood Bank, Foundation for Biomedical Research, Academy of Athens; Department of Immunology and National Tissue Typing Center, "G. Gennimatas" General Hospital; Department of Microbiology, Medical School, University of Athens, Athens, Greece.

出版信息

Transfusion. 2014 Jan;54(1):211-23. doi: 10.1111/trf.12239. Epub 2013 May 21.

Abstract

BACKGROUND

Cord blood (CB) units are stored from weeks to years in liquid- or vapor-phase nitrogen until they are used for transplantation. We examined the effects of cryostorage in a mechanical freezer at -150°C on critical quality control variables of CB collections to investigate the possible use of mechanical freezers at -150°C as an alternative to storage in liquid- (or vapor-) phase nitrogen.

STUDY DESIGN AND METHODS

A total of 105 CB units were thawed and washed at different time intervals (6, 12, 24, and 36 months). For every thawed CB unit, samples were removed and cell enumeration (total nucleated cells [TNCs], mononuclear cells [MNCs], CD34+, CD133+) was performed. In addition, viability was obtained with the use of flow cytometry, and recoveries were calculated. Also, total absolute colony-forming unit counts were performed and progenitor cell recoveries were studied by clonogenic assays.

RESULTS

Significant differences (p < 0.05) were observed in certain variables (TNCs, MNC numbers, viability) when they were examined in relation with time intervals, while others (CD34+, CD133+) were relatively insensitive (p = NS) to the duration of time interval the CB units were kept in cryostorage condition.

CONCLUSIONS

The data presented suggest that cryopreservation of CB units in a mechanical freezer at -150°C may represent an alternative cryostorage condition for CB cryopreservation.

摘要

背景

脐带血(CB)单位在液态或气相氮中储存数周到数年,直到用于移植。我们研究了在-150°C 的机械冷冻器中冷冻储存对 CB 采集的关键质量控制变量的影响,以探讨在-150°C 的机械冷冻器作为液态(或气相)氮储存替代品的可能性。

研究设计和方法

总共解冻了 105 个 CB 单位,并在不同的时间间隔(6、12、24 和 36 个月)进行了清洗。对于每个解冻的 CB 单位,都取出样本进行细胞计数(总核细胞[TNCs]、单核细胞[MNCs]、CD34+、CD133+)。此外,使用流式细胞术获得了活力,并计算了回收率。还进行了总绝对集落形成单位计数,并通过克隆形成测定研究了祖细胞回收率。

结果

当检查与时间间隔的关系时,某些变量(TNCs、MNC 数量、活力)观察到显著差异(p<0.05),而其他变量(CD34+、CD133+)相对不敏感(p=NS)于 CB 单位在冷冻储存条件下保持的时间间隔的持续时间。

结论

所提供的数据表明,在-150°C 的机械冷冻器中冷冻保存 CB 单位可能代表 CB 冷冻保存的另一种冷冻储存条件。