Suppr超能文献

车削冠-齿系统中牙冠设计和界面 lute 参数对应力状态的影响:有限元分析。

Effect of the crown design and interface lute parameters on the stress-state of a machined crown-tooth system: a finite element analysis.

机构信息

Academic Unit of Restorative Dentistry, The School of Clinical Dentistry, Claremont Crescent, Sheffield, UK.

出版信息

Dent Mater. 2013 Aug;29(8):e123-31. doi: 10.1016/j.dental.2013.04.002. Epub 2013 May 23.

Abstract

The effect of preparation design and the physical properties of the interface lute on the restored machined ceramic crown-tooth complex are poorly understood. The aim of this work was to determine, by means of three-dimensional finite element analysis (3D FEA) the effect of the tooth preparation design and the elastic modulus of the cement on the stress state of the cemented machined ceramic crown-tooth complex. The three-dimensional structure of human premolar teeth, restored with adhesively cemented machined ceramic crowns, was digitized with a micro-CT scanner. An accurate, high resolution, digital replica model of a restored tooth was created. Two preparation designs, with different occlusal morphologies, were modeled with cements of 3 different elastic moduli. Interactive medical image processing software (mimics and professional CAD modeling software) was used to create sophisticated digital models that included the supporting structures; periodontal ligament and alveolar bone. The generated models were imported into an FEA software program (hypermesh version 10.0, Altair Engineering Inc.) with all degrees of freedom constrained at the outer surface of the supporting cortical bone of the crown-tooth complex. Five different elastic moduli values were given to the adhesive cement interface 1.8GPa, 4GPa, 8GPa, 18.3GPa and 40GPa; the four lower values are representative of currently used cementing lutes and 40GPa is set as an extreme high value. The stress distribution under simulated applied loads was determined. The preparation design demonstrated an effect on the stress state of the restored tooth system. The cement elastic modulus affected the stress state in the cement and dentin structures but not in the crown, the pulp, the periodontal ligament or the cancellous and cortical bone. The results of this study suggest that both the choice of the preparation design and the cement elastic modulus can affect the stress state within the restored crown-tooth complex.

摘要

制备设计和界面 lute 的物理性能对修复加工陶瓷冠 - 牙复合体的影响了解甚少。本工作的目的是通过三维有限元分析(3D FEA)确定牙制备设计和粘结剂弹性模量对粘结加工陶瓷冠 - 牙复合体的应力状态的影响。用微 CT 扫描仪对用粘结剂粘结加工陶瓷冠修复的人前磨牙的三维结构进行数字化。创建了一个准确、高分辨率、数字化的修复牙模型。用 3 种不同弹性模量的粘结剂对具有不同咬合形态的两种制备设计进行建模。交互式医学图像处理软件(mimics 和专业 CAD 建模软件)用于创建复杂的数字模型,包括支持结构;牙周膜和牙槽骨。生成的模型被导入到有限元分析软件程序(hypermesh 版本 10.0,Altair Engineering Inc.)中,所有自由度都受到冠 - 牙复合体外表面的限制。为粘结剂界面赋予了 5 种不同的弹性模量值 1.8GPa、4GPa、8GPa、18.3GPa 和 40GPa;前 4 个值代表目前使用的粘结剂 lute,40GPa 设定为极高值。确定了模拟应用载荷下的应力分布。制备设计对修复牙系统的应力状态有影响。粘结剂弹性模量影响粘结剂和牙本质结构中的应力状态,但不影响冠、牙髓、牙周膜或松质骨和皮质骨。本研究结果表明,制备设计的选择和粘结剂弹性模量都可以影响修复后的冠 - 牙复合体内部的应力状态。

文献AI研究员

20分钟写一篇综述,助力文献阅读效率提升50倍。

立即体验

用中文搜PubMed

大模型驱动的PubMed中文搜索引擎

马上搜索

文档翻译

学术文献翻译模型,支持多种主流文档格式。

立即体验