Suppr超能文献

[电感耦合等离子体质谱法(ICP-MS)用于放射性核素体内污染尿液诊断的应用及局限性]

[Interest and limits of inductively coupled plasma mass spectrometry (ICP-MS) for urinary diagnosis of radionuclide internal contamination].

作者信息

Lecompte Yannick, Bohand Sandra, Laroche Pierre, Cazoulat Alain

机构信息

Service de protection radiologique des armées, Clamart, France.

出版信息

Ann Biol Clin (Paris). 2013 May-Jun;71(3):269-81. doi: 10.1684/abc.2013.0827.

Abstract

After a review of radiometric reference methods used in radiotoxicology, analytical performance of inductively coupled plasma mass spectrometry (ICP-MS) for the workplace urinary diagnosis of internal contamination by radionuclides are evaluated. A literature review (covering the period from 2000 to 2012) is performed to identify the different applications of ICP-MS in radiotoxicology for urine analysis. The limits of detection are compared to the recommendations of the International commission on radiological protection (ICRP 78: "Individual monitoring for internal exposure of workers"). Except one publication describing the determination of strontium-90 (β emitter), all methods using ICP-MS reported in the literature concern actinides (α emitters). For radionuclides with a radioactive period higher than 10(4) years, limits of detection are most often in compliance with ICRP publication 78 and frequently lower than radiometric methods. ICP-MS allows the specific determination of plutonium-239 + 240 isotopes which cannot be discriminated by α spectrometry. High resolution ICP-MS can also measure uranium isotopic ratios in urine for total uranium concentrations lower than 20 ng/L. The interest of ICP-MS in radiotoxicology concerns essentially the urinary measurement of long radioactive period actinides, particularly for uranium isotope ratio determination and 239 and 240 plutonium isotopes discrimination. Radiometric methods remain the most efficient for the majority of other radionuclides.

摘要

在回顾了放射毒理学中使用的放射性参考方法后,对电感耦合等离子体质谱法(ICP-MS)用于工作场所尿液中放射性核素内污染诊断的分析性能进行了评估。进行了一项文献综述(涵盖2000年至2012年期间),以确定ICP-MS在放射毒理学中用于尿液分析的不同应用。将检测限与国际放射防护委员会(ICRP 78:“工人内照射个人监测”)的建议进行了比较。除了一篇描述锶-90(β发射体)测定的出版物外,文献中报道的所有使用ICP-MS的方法都涉及锕系元素(α发射体)。对于半衰期高于10⁴年的放射性核素,检测限大多符合ICRP第78号出版物的要求,并且通常低于放射性测量方法。ICP-MS能够特异性测定钚-239 + 240同位素,而α能谱法无法区分这两种同位素。高分辨率ICP-MS还可以在尿液总铀浓度低于20 ng/L时测量铀同位素比率。ICP-MS在放射毒理学中的意义主要在于对长半衰期锕系元素的尿液测量,特别是用于铀同位素比率测定和钚-239和钚-240同位素的区分。对于大多数其他放射性核素,放射性测量方法仍然是最有效的。

文献检索

告别复杂PubMed语法,用中文像聊天一样搜索,搜遍4000万医学文献。AI智能推荐,让科研检索更轻松。

立即免费搜索

文件翻译

保留排版,准确专业,支持PDF/Word/PPT等文件格式,支持 12+语言互译。

免费翻译文档

深度研究

AI帮你快速写综述,25分钟生成高质量综述,智能提取关键信息,辅助科研写作。

立即免费体验