Naser Asieh Zamani, Mehr Bahar Behdad
Torabinejad Dental Research Center, Department of Oromaxillofacial Radiology, School of dentistry, Isfahan University of Medical Sciences, Isfahan, Iran.
Dent Res J (Isfahan). 2013 Jan;10(1):15-9. doi: 10.4103/1735-3327.111759.
Cross- sectional tomograms have been used for optimal pre-operative planning of dental implant placement. The aim of the present study was to assess the accuracy of Cone Beam Computed Tomography (CBCT) measurements of specific distances around the mandibular canal by comparing them to those obtained from Multi-Slice Computed Tomography (MSCT) images.
Ten hemi-mandible specimens were examined using CBCT and MSCT. Before imaging, wires were placed at 7 locations between the anterior margin of the third molar and the anterior margin of the second premolar as reference points. Following distances were measured by two observers on each cross-sectional CBCT and MSCT image: Mandibular Width (W), Length (L), Upper Distance (UD), Lower Distance (LD), Buccal Distance (BD), and Lingual Distance (LID). The obtained data were evaluated using SPSS software, applying paired t-test and intra-class correlation coefficient (ICC).
There was a significant difference between the values obtained by MSCT and CBCT measurement for all areas such as H, W, UD, LD, BD, and LID, (P < 0.001), with a difference less than 1 mm. The ICC for all distances by both techniques, measured by a single observer with a one week interval and between 2 observers was 99% and 98%, respectively. Comparing the obtained data of both techniques indicates that the difference between two techniques is 2.17% relative to MSCT.
The results of this study showed that there is significant difference between measurements obtained by CBCT and MSCT. However, the difference is not clinically significant.
横断面断层扫描已用于牙种植体植入的最佳术前规划。本研究的目的是通过将锥形束计算机断层扫描(CBCT)测量下颌管周围特定距离的结果与多层螺旋计算机断层扫描(MSCT)图像获得的结果进行比较,来评估其准确性。
使用CBCT和MSCT对10个半下颌骨标本进行检查。在成像前,将金属丝放置在第三磨牙前缘和第二前磨牙前缘之间的7个位置作为参考点。两名观察者在每个CBCT和MSCT横断面图像上测量以下距离:下颌宽度(W)、长度(L)、上距离(UD)、下距离(LD)、颊侧距离(BD)和舌侧距离(LID)。使用SPSS软件对获得的数据进行评估,应用配对t检验和组内相关系数(ICC)。
MSCT和CBCT测量所得的所有区域(如H、W、UD、LD、BD和LID)的值之间存在显著差异(P < 0.001),差异小于1mm。由一名观察者间隔一周以及两名观察者测量的两种技术所有距离的ICC分别为99%和98%。比较两种技术获得的数据表明,相对于MSCT,两种技术之间的差异为2.17%。
本研究结果表明,CBCT和MSCT测量结果之间存在显著差异。然而,这种差异在临床上并不显著。