Amalan Arul, Ginjupalli Kishore, Upadhya Nagaraja
Department of Dental Materials, Faculty of Dentistry, Melaka Manipal Medical College, Manipal University, Manipal, Karnataka, India.
Dent Res J (Isfahan). 2013 Jan;10(1):65-73. doi: 10.4103/1735-3327.111795.
Addition of disinfectant to irreversible hydrocolloid impression materials can eliminate the disinfection step to avoid dimensional changes associated with it. The aim of the present study was to evaluate the effect of various disinfectant mixing liquids on the properties of commercially available irreversible hydrocolloid impression materials.
Four commercially available irreversible hydrocolloid impression materials (Zelgan, Vignette, Tropicalgin, and Algitex) were mixed with disinfectant liquid containing chlorhexidine (0.1 and 0.2%) and sodium hypochlorite (0.1 and 0.5%). After mixing with disinfectant liquids, materials were evaluated for pH changes during gelation, gelation time, flow, gel strength, permanent deformation and detail reproduction.
Significant changes in gelation time were observed in irreversible hydrocolloid impression materials upon mixing with disinfectant liquids. In general, chlorhexidine increased the gelation time, whereas sodium hypochlorite reduced it. However, no significant changes in the flow were observed both with chlorhexidine and sodium hypochlorite. Gel strength was found to decrease when mixed with chlorhexidine, whereas an increase in gel strength was observed upon mixing with sodium hypochlorite. Permanent deformation of the most irreversible hydrocolloid impression materials was below the specification limit even after mixing with disinfectant liquids. Sodium hypochlorite significantly reduced the surface detail reproduction, whereas no change in detail reproduction was observed with chlorhexidine.
Chlorhexidine solution can be used to mix irreversible hydrocolloid impression materials in regular dental practice as it did not significantly alter the properties. This may ensure effective disinfection of impressions.
在不可逆水胶体印模材料中添加消毒剂可省去消毒步骤,避免与之相关的尺寸变化。本研究的目的是评估各种消毒混合液对市售不可逆水胶体印模材料性能的影响。
将四种市售不可逆水胶体印模材料(Zelgan、Vignette、Tropicalgin和Algitex)与含有洗必泰(0.1%和0.2%)和次氯酸钠(0.1%和0.5%)的消毒液体混合。与消毒液体混合后,评估材料在凝胶化过程中的pH变化、凝胶化时间、流动性、凝胶强度、永久变形和细节再现性。
不可逆水胶体印模材料与消毒液体混合后,凝胶化时间出现显著变化。一般来说,洗必泰会延长凝胶化时间,而次氯酸钠会缩短凝胶化时间。然而,洗必泰和次氯酸钠对流动性均未产生显著影响。发现与洗必泰混合时凝胶强度降低,而与次氯酸钠混合时凝胶强度增加。即使与消毒液体混合后,大多数不可逆水胶体印模材料的永久变形仍低于规格限值。次氯酸钠显著降低了表面细节再现性,而洗必泰对细节再现性无影响。
在常规牙科操作中,洗必泰溶液可用于混合不可逆水胶体印模材料,因为它不会显著改变材料性能。这可确保印模的有效消毒。