Suppr超能文献

在一种新型体外无牙颌模型上测试义齿设计和固定剂对下颌全口义齿固位的影响。

The effect of denture design and fixatives on the retention of mandibular complete dentures tested on a novel in-vitro edentulous model.

作者信息

Johnson A, Al-Kaisy N, Miller C A, Martin N

机构信息

School of Clinical Dentistry, University of Sheffield, Claremont Cresent, Sheffield.

出版信息

Eur J Prosthodont Restor Dent. 2013 Jun;21(2):64-74.

Abstract

The aim of this study was to evaluate the effect of the design (extension and adaptation) of a mandibular complete acrylic denture and the use of denture adhesives using a novel in-vitro edentulous model. The model is a highly anatomically accurate replica based on a moderately resorbed human mandibular edentulous arch. The model has been designed and fabricated by means of an elaborate clinical and technical process that employs synthetic elastomeric materials with properties that attempts to reproduce in-vitro characteristics of the soft tissues overlying the ridges and immediate reflected tissues. This model was used to measure and compare the retention of mandibular dentures ofvarying designs (well-fitting, over- and under-extended) with and without the aid of denture fixatives. Retention tests were conducted with different volumes of artificial saliva at a cross head speed of 50 mm/min with 4 equidistant holding points on the denture occlusal surface, using a universal tensile testing machine in an axial pull direction. The effect of three denture adhesives on denture retention was also tested on the same denture types at different times over a period of 5 hours and beyond. The in-vitro model presented can be effectively used to test the retention of mandibular complete dentures. The speed of dislodgement force and amount of saliva are important variables in mandibular denture retention. The retention of well-fitting dentures was statistically higher than that of ill-fitting dentures. A significantly higher retention force was needed to dislodge mandibular dentures (well and ill-fitting dentures) when using a denture adhesive.

摘要

本研究的目的是使用一种新型体外无牙颌模型,评估下颌全口丙烯酸义齿的设计(伸展和适配)以及义齿粘合剂的使用效果。该模型是基于中度吸收的人类下颌无牙颌弓制作的高度解剖学精确复制品。该模型通过精心的临床和技术流程设计并制作而成,采用了合成弹性体材料,其特性旨在重现覆盖牙槽嵴的软组织和即刻反射组织的体外特征。该模型用于测量和比较不同设计(贴合良好、伸展过度和伸展不足)的下颌义齿在使用和不使用义齿固定剂情况下的固位力。使用万能拉伸试验机,在轴向拉伸方向上,以50毫米/分钟的十字头速度,在义齿咬合面上设置4个等距固定点,用不同体积的人工唾液进行固位测试。还在5小时及更长时间内的不同时间,对相同类型的义齿测试了三种义齿粘合剂对义齿固位的影响。所呈现的体外模型可有效用于测试下颌全口义齿的固位力。脱位力的速度和唾液量是下颌义齿固位的重要变量。贴合良好的义齿的固位力在统计学上高于贴合不良的义齿。使用义齿粘合剂时,脱位下颌义齿(贴合良好和贴合不良的义齿)需要显著更高的固位力。

文献AI研究员

20分钟写一篇综述,助力文献阅读效率提升50倍。

立即体验

用中文搜PubMed

大模型驱动的PubMed中文搜索引擎

马上搜索

文档翻译

学术文献翻译模型,支持多种主流文档格式。

立即体验