Department of Rheumatoid Diseases, Turku University Hospital, Paimio, Finland.
Scand J Surg. 2013;102(3):197-203. doi: 10.1177/1457496913491874.
Recent advancements in manufacturing technology have enabled more precise tolerances and surface finishes using metal-on-metal bearing surfaces in total hip arthroplasty. The aim of this study was to compare the level of metal ions in urine after implantation of a 28-mm metal-on-metal bearing manufactured from high-carbon wrought alloy and a 28-mm metal-on-polyethylene bearing.
A total of 92 total hip arthroplasty patients were prospectively randomized into two groups: those receiving metal-on-metal bearings and those receiving metal-on-polyethylene bearings. Chromium, cobalt, and molybdenum ion levels in urine were measured preoperatively and at 1 year and 2 years postoperatively.
In the metal-on-polyethylene group, there was a slight increase in mean chromium and cobalt concentrations at 2-year follow-up compared to the preoperative level (p = 0.02 for both chromium and cobalt). In the metal-on-metal group, there was a 15-fold increase in chromium and a 26-fold increase in cobalt at 2-year follow-up compared to the preoperative level (p < 0.001 for both chromium and cobalt). However, the quantity of chromium and cobalt in urine from the metal-on-metal group was not higher at 2-year follow-up than at 1-year follow-up (p = 0.5 and p = 0.6, respectively).
The 28-mm metal-on-metal bearings yield chromium and cobalt concentrations in urine that can be higher than those recommended for occupational exposure. However, our results also indicate that a steady state in wear and ion production using metal-on-metal total hip arthroplasty can occur.
最近制造技术的进步使得在全髋关节置换术中使用金属对金属的轴承表面能够实现更精确的公差和表面光洁度。本研究的目的是比较植入由高碳钢锻造合金制成的 28mm 金属对金属轴承和 28mm 金属对聚乙烯轴承后尿液中的金属离子水平。
共有 92 例全髋关节置换术患者前瞻性随机分为两组:一组接受金属对金属轴承,另一组接受金属对聚乙烯轴承。术前和术后 1 年和 2 年测量尿液中的铬、钴和钼离子水平。
在金属对聚乙烯组中,与术前相比,术后 2 年随访时平均铬和钴浓度略有增加(铬和钴均 p = 0.02)。在金属对金属组中,与术前相比,术后 2 年随访时铬和钴的浓度分别增加了 15 倍和 26 倍(铬和钴均 p < 0.001)。然而,金属对金属组在术后 2 年随访时的尿液中铬和钴的量与术后 1 年随访时相比没有增加(分别为 p = 0.5 和 p = 0.6)。
28mm 金属对金属轴承产生的铬和钴浓度可能高于职业暴露的推荐浓度。然而,我们的结果也表明,金属对金属全髋关节置换术后的磨损和离子产生可能会达到稳定状态。