Al-Hwiesh Abdullah Khalaf
Department of Internal Medicine, Nephrology Division, King Fahd University Hospital, Dammam University, Saudi Arabia.
Perit Dial Int. 2014 Mar-Apr;34(2):204-11. doi: 10.3747/pdi.2012.00160. Epub 2013 Oct 1.
Insertion of the peritoneal dialysis (PD) catheter by a nephrologist has been encouraged by several studies. The ultimate goal is to provide safe, timely, and effective catheter insertion without an unduly long wait time or delay. The success of PD depends partly on the ease of catheter insertion. We developed a new technique for percutaneous PD catheter insertion by nephrologists. Our new technique, in addition to being easy, proved to be safe and to eliminate the need for the peel-away sheath.
Data were collected prospectively on all patients having a PD catheter inserted by a nephrologist using our new technique (40 catheters in 38 patients). All catheters were evaluated for infectious and mechanical complications.
The mean duration of the procedure from skin sterilization to the end of insertion was 24 ± 3 minutes. No bowel perforation or serious hemorrhage was recorded. Poor initial drainage was recorded in 12.5% of the catheters (n = 5) during the 4 weeks after insertion. The incidence of early exit-site leakage was 2.5% (1 catheter). Episodes of exit-site infection occurred in 5.0% and 12.5% of catheters (within 1 month and by the end of study period respectively). Two episodes of peritonitis were reported by the end of the 12-month period. Catheter survival was 95.0% and 87.5% at 6 months and 12 months respectively.
Percutaneous bedside placement of PD catheters using our new technique is safe and carries less morbidity in terms of bowel perforation, catheter-related infection, and exit-site leak. In addition, our new technique appears to have a high success rate and to offer considerable savings in terms of operating time.
多项研究鼓励由肾病学家插入腹膜透析(PD)导管。最终目标是在不过度长时间等待或延迟的情况下,提供安全、及时且有效的导管插入。PD的成功部分取决于导管插入的难易程度。我们开发了一种由肾病学家进行经皮PD导管插入的新技术。我们的新技术除了操作简便外,还被证明是安全的,并且无需使用可剥离鞘。
前瞻性收集了所有使用我们的新技术由肾病学家插入PD导管的患者的数据(38例患者共40根导管)。对所有导管的感染和机械并发症进行评估。
从皮肤消毒到插入结束的平均操作时间为24±3分钟。未记录到肠穿孔或严重出血情况。插入后4周内,12.5%的导管(n = 5)出现初始引流不佳。早期出口部位渗漏的发生率为2.5%(1根导管)。出口部位感染发生率分别为5.0%(1个月内)和12.5%(研究期结束时)。12个月期末报告了2例腹膜炎病例。导管在6个月和12个月时的生存率分别为95.0%和87.5%。
使用我们的新技术在床边经皮放置PD导管是安全的,在肠穿孔、导管相关感染和出口部位渗漏方面发病率较低。此外,我们的新技术似乎成功率很高,并且在操作时间方面节省可观。