Department of Analytical Chemistry and Organic Chemistry, Universitat Rovira i Virgili, Sescelades Campus, Marcel·lí Domingo s/n, 43007 Tarragona, Spain.
Talanta. 2013 Nov 15;116:931-6. doi: 10.1016/j.talanta.2013.07.080. Epub 2013 Aug 9.
A method for the quantitative determination of five iodinated X-ray contrast media (ICMs) in sewage was developed by solid-phase extraction and high-performance liquid chromatography-tandem mass spectrometry. A fused-core analytical column was successfully applied for the first time for the separation of ICMs. Oasis HLB was selected from the sorbents tested because of its higher recoveries. The optimized method allowed the determination of the ICMs at low ng/L levels in both influent and effluent sewage, with detection limits of 40 ng/L and 10 ng/L for most compounds in influent and effluent sewage, respectively. The five ICMs studied were determined in all samples analysed, with iopromide being the analyte found at the highest concentration (8.9 µg/L), while iopamidol was the analyte found at lowest concentration (1.3 µg/L) in influent sewage. Effluent sewage did not show a significant decrease in ICM concentrations.
建立了固相萃取-高效液相色谱-串联质谱法同时测定污水中 5 种碘造影剂(ICM)的方法。首次成功应用熔融核分析柱对 ICM 进行分离。由于其具有更高的回收率,从测试的吸附剂中选择 Oasis HLB。该优化方法允许在进水和出水污水中以低 ng/L 水平测定 ICM,进水和出水污水中大多数化合物的检测限分别为 40ng/L 和 10ng/L。在所分析的所有样品中均测定了研究的 5 种 ICM,其中在进水污水中发现的浓度最高的分析物为碘普罗胺(8.9µg/L),而在进水污水中发现的浓度最低的分析物为碘海醇(1.3µg/L)。出水污水中 ICM 浓度没有明显下降。