Suppr超能文献

注射器和聚集物过滤器给药对输注的自体新鲜猫红细胞存活率的影响。

Effect of syringe and aggregate filter administration on survival of transfused autologous fresh feline red blood cells.

作者信息

Heikes Brandon W, Ruaux Craig G

机构信息

College of Veterinary Medicine, Oregon State University, Corvallis, OR, 97330.

出版信息

J Vet Emerg Crit Care (San Antonio). 2014 Mar-Apr;24(2):162-7. doi: 10.1111/vec.12115. Epub 2013 Nov 13.

Abstract

OBJECTIVE

To assess the effect of transfusion using a syringe and microaggregate filter on short-term survival and circulating half-life of autologous feline RBCs.

DESIGN

Prospective, internally controlled, observational study.

SETTING

A University Teaching Hospital

ANIMALS

Six apparently healthy, owned cats.

INTERVENTIONS

Blood collection by jugular venipuncture. Transfusion with labeled, autologous, fresh RBCs.

MEASUREMENTS AND MAIN RESULTS

Anticoagulated whole blood (35 mL/cat) was collected in 2 equal aliquots. RBCs were washed and labeled at 2 different biotin densities, before suspension in autologous plasma. Labeled RBCs were then transfused using 2 methods, gravity flow and pump delivery using a 20 mL syringe and 18 μm microaggregate filter. Whole blood samples were collected from each cat at 2-hour intervals for 12 hours following completion of the transfusions. Additional samples were collected at weekly intervals up to 6 weeks to assess circulating half-life of the transfused cells. Cell survival was assessed via flow cytometry. The proportion of transfused cells remaining in each of the 2 populations was measured. Biotinylated RBCs were readily detected in all cats over the 6-week sampling period. There was a significant decrease in both populations of labeled cells over the 6-week period (P < 0.01), as expected. There was no difference in probability that the RBCs would survive up to 12 hours immediately following transfusion, and no significant difference in survival between the 2 groups over 6 weeks. The average half-life of all labeled cells was approximately 23 days.

CONCLUSIONS

We conclude that, in contrast to findings from dogs, transfusion of autologous feline RBCs using a syringe + aggregate filter method does not significantly impact short- or long-term survival of the transfused cells.

摘要

目的

评估使用注射器和微聚体过滤器输血对自体猫红细胞短期存活及循环半衰期的影响。

设计

前瞻性、自身对照、观察性研究。

地点

一所大学教学医院

动物

6只表面健康的家养猫。

干预措施

通过颈静脉穿刺采血。输注标记的自体新鲜红细胞。

测量指标及主要结果

将抗凝全血(35毫升/只猫)分成2等份采集。红细胞经洗涤后,以2种不同的生物素密度进行标记,然后悬浮于自体血浆中。随后使用2种方法输注标记的红细胞,即重力输注法以及使用20毫升注射器和18微米微聚体过滤器的泵注法。输血完成后,每隔2小时从每只猫采集全血样本,共采集12小时。另外,每周采集样本,持续6周,以评估输注细胞的循环半衰期。通过流式细胞术评估细胞存活情况。测量2个细胞群体中剩余的输注细胞比例。在6周的采样期内,所有猫均能轻松检测到生物素化红细胞。正如预期的那样,在6周期间,2个标记细胞群体均显著减少(P < 0.01)。输血后红细胞存活至12小时的概率在两组之间无差异,且两组在6周内的存活率也无显著差异。所有标记细胞的平均半衰期约为23天。

结论

我们得出结论,与犬类的研究结果不同,使用注射器 + 聚集体过滤器方法输注自体猫红细胞对输注细胞的短期或长期存活没有显著影响。

文献AI研究员

20分钟写一篇综述,助力文献阅读效率提升50倍。

立即体验

用中文搜PubMed

大模型驱动的PubMed中文搜索引擎

马上搜索

文档翻译

学术文献翻译模型,支持多种主流文档格式。

立即体验