PURPOSE

Limiting the size of the x-ray field during radiography is an important radiation safety practice and the sole responsibility of the radiologic technologist. Collimation reduces the volume of tissue irradiated and therefore reduces patient exposure and improves image quality. The purpose of the research experiment was to investigate the effect of decreasing the x-ray field size on patient dosimetry during lumbar spine imaging.

METHODS

The x-ray field size was decreased from 14 × 17 in (35 × 43 cm) to 8 × 17 in (20 × 43 cm) with an increase in mAs to maintain exposure to the image receptor. Patient dosimetry was investigated by measuring the thermoluminescent dosimeter (TLD) exposure to the abdominal region of an anthropomorphic adult male phantom. Seven TLD chips were placed in the abdominal region, exposed, and replaced for each of 10 exposures, totaling 70 exposed TLDs. A 2-way factorial analysis of variance for independent samples was calculated to determine whether x-ray field size and the TLD locations altered the milliroentgen (mR) reading.

RESULTS

The TLDs located closest to the lumbar spine yielded no significant change in patient dose for the 8 × 17 in (20 × 43 cm) x-ray field size following the increase in mAs. However, the TLDs located closest to the lateral edge of the 8 × 17 in (20 × 43 cm) collimated x-ray beam received a significantly (P < .001) lower mR exposure (> 60%).

CONCLUSION

Radiologic technologists should make considerable effort to limit the x-ray field size to the region of interest to reduce patient exposure.

摘要

目的

在放射摄影过程中限制X射线照射野的大小是一项重要的辐射安全措施,也是放射技师的唯一责任。准直可减少受照射组织的体积,从而减少患者受照剂量并提高图像质量。本研究实验的目的是调查在腰椎成像过程中减小X射线照射野大小对患者剂量测定的影响。

方法

将X射线照射野大小从14×17英寸(35×43厘米)减小到8×17英寸(20×43厘米),同时增加毫安秒(mAs)以维持对图像接收器的照射量。通过测量热释光剂量计(TLD)对成年男性仿真人体模型腹部区域的照射量来研究患者剂量测定情况。在腹部区域放置7个TLD芯片,进行10次每次曝光后更换芯片,总共70个TLD被曝光。计算独立样本的双向析因方差分析,以确定X射线照射野大小和TLD位置是否会改变毫伦琴(mR)读数。

结果

对于8×17英寸(20×43厘米)的X射线照射野大小,在增加mAs后,最靠近腰椎的TLD所测得的患者剂量无显著变化。然而,最靠近8×17英寸(20×43厘米)准直X射线束外侧边缘的TLD所接受的mR照射量显著降低(P <.001)(超过60%)。

结论

放射技师应大力努力将X射线照射野大小限制在感兴趣区域,以减少患者受照剂量。