Suppr超能文献

超高效液相色谱/电喷雾电离串联质谱法测定大豆和豆类中的151种农药。

Ultra-high performance liquid chromatography/ electrospray ionization-tandem mass spectrometry determination of 151 pesticides in soybeans and pulses.

作者信息

Wang Jian, Cheung Wendy, Chow Willis

机构信息

Canadian Food Inspection Agency, Calgary Laboratory, 3650-36th Street NW, Calgary, Alberta, Canada T2L 2L1.

出版信息

J AOAC Int. 2013 Sep-Oct;96(5):1114-33. doi: 10.5740/jaoacint.12-465.

Abstract

This paper presents the application of ultra-high performance LC (UHPLC) and MS for the determination of 151 pesticides in soybeans and pulses. A core-shell particle (2.6 micro m particle size) column and a fully porous sub-2 microm (1.7 microm particle size) column showed comparable performance in chromatographic resolution and separation, increasing selectivity, and reducing analysis time. UHPLC was coupled with either a triple quadrupole mass analyzer (MS/MS) or a quadrupole Orbitrap (namely Orbital trap) mass spectrometer (Q-Orbitrap MS), which possesses fast data acquisition capability. Both configurations yielded analytical run times of < or =14 min. Soybean and pulse samples were analyzed and quantitated for pesticide residues using the QuEChERS (Quick, Easy, Cheap, Effective, Rugged, and Safe) procedure, UHPLC/electrospray ionization (ESI)-MS/MS, and matrix-matched standard calibration curves (in an analytical range of 5-500 microg/kg) with isotopically-labeled standards or a chemical analog as internal standards. The method performance parameters that included overall recovery, intermediate precision, and measurement uncertainty were evaluated according to a nested design experiment. Approximately 89% of the pesticides studied had recoveries between 81 and 110%; 95%, had intermediate precision < or =20%; and 93% showed measurement uncertainty < or =40%. From a pilot study of 100 samples, eight tested positive by UHPLCIESI-MS/MS for carbendazim, methomyl, or imidacloprid. These pesticides were further confirmed using UHPLC/ESI-Q-Orbitrap MS based on accurate mass measurement with mass error < or =5 ppm.

摘要

本文介绍了超高效液相色谱(UHPLC)和质谱(MS)在测定大豆和豆类中151种农药的应用。核壳颗粒(粒径2.6微米)柱和全多孔亚2微米(粒径1.7微米)柱在色谱分辨率和分离、提高选择性以及减少分析时间方面表现出相当的性能。UHPLC与三重四极杆质量分析仪(MS/MS)或四极杆轨道阱(即轨道阱)质谱仪(Q-Orbitrap MS)联用,后者具有快速数据采集能力。两种配置的分析运行时间均≤14分钟。使用QuEChERS(快速、简便、廉价、有效、耐用和安全)方法、UHPLC/电喷雾电离(ESI)-MS/MS以及基质匹配标准校准曲线(分析范围为5-500微克/千克),以同位素标记标准品或化学类似物作为内标物,对大豆和豆类样品中的农药残留进行分析和定量。根据嵌套设计实验评估了包括总回收率、中间精密度和测量不确定度在内的方法性能参数。所研究的农药中约89%的回收率在81%至110%之间;95%的中间精密度≤20%;93%的测量不确定度≤40%。在对100个样品的初步研究中,有8个样品经UHPLC/ESI-MS/MS检测多菌灵、灭多威或吡虫啉呈阳性。基于质量误差≤5 ppm的精确质量测量,使用UHPLC/ESI-Q-Orbitrap MS对这些农药进行了进一步确认。

相似文献

文献AI研究员

20分钟写一篇综述,助力文献阅读效率提升50倍。

立即体验

用中文搜PubMed

大模型驱动的PubMed中文搜索引擎

马上搜索

文档翻译

学术文献翻译模型,支持多种主流文档格式。

立即体验