Abstract

Bifunctional tetrameric complexes of monoclonal antibodies were used to stain cells for flow cytometry. These complexes consist of two different mouse monoclonal IgG1 antibodies (one with specificity for a cell surface antigen, the other with specificity for a fluorochrome) cross-linked by two molecules of a monoclonal rat anti-mouse IgG1. The use of this immunological approach to cross-link fluorochromes to cell surface antigens was studied with tetrameric complexes containing Leu-3a or Leu-2a antibodies and monoclonal antibodies specific for the fluorochromes B- and R-phycoerythrin. The ability of such cyclic immune complexes to stain T-cell subset antigens on human peripheral blood lymphocytes was demonstrated in single and double-staining experiments. The results demonstrate that tetrameric antibody complexes provide a simple and efficient alternative to covalently labeled antibodies for the flow cytofluorimetric analysis of cell-surface antigens.