磁共振灌注成像的可重复性。

Reproducibility of magnetic resonance perfusion imaging.

作者信息

Zhang Xiaomeng, Pagel Mark D, Baker Amanda F, Gillies Robert J

机构信息

Biomedical Engineering Graduate Interdisciplinary Program, University of Arizona, Tucson, Arizona, United States of America ; H. Lee Moffitt Cancer Center & Research Institute, Tampa, Florida, United States of America.

Biomedical Engineering Graduate Interdisciplinary Program, University of Arizona, Tucson, Arizona, United States of America ; Department of Chemistry and Biochemistry, University of Arizona, Tucson, Arizona, United States of America ; University of Arizona Cancer Center, University of Arizona, Tucson, Arizona, United States of America.

出版信息

PLoS One. 2014 Feb 25;9(2):e89797. doi: 10.1371/journal.pone.0089797. eCollection 2014.

Abstract

Dynamic MR biomarkers (T2*-weighted or susceptibility-based and T1-weighted or relaxivity-enhanced) have been applied to assess tumor perfusion and its response to therapies. A significant challenge in the development of reliable biomarkers is a rigorous assessment and optimization of reproducibility. The purpose of this study was to determine the measurement reproducibility of T1-weighted dynamic contrast-enhanced (DCE)-MRI and T2*-weighted dynamic susceptibility contrast (DSC)-MRI with two contrast agents (CA) of different molecular weight (MW): gadopentetate (Gd-DTPA, 0.5 kDa) and Gadomelitol (P792, 6.5 kDa). Each contrast agent was tested with eight mice that had subcutaneous MDA-MB-231 breast xenograft tumors. Each mouse was imaged with a combined DSC-DCE protocol three times within one week to achieve measures of reproducibility. DSC-MRI results were evaluated with a contrast to noise ratio (CNR) efficiency threshold. There was a clear signal drop (>95% probability threshold) in the DSC of normal tissue, while signal changes were minimal or non-existent (<95% probability threshold) in tumors. Mean within-subject coefficient of variation (wCV) of relative blood volume (rBV) in normal tissue was 11.78% for Gd-DTPA and 6.64% for P792. The intra-class correlation coefficient (ICC) of rBV in normal tissue was 0.940 for Gd-DTPA and 0.978 for P792. The inter-subject correlation coefficient was 0.092. Calculated K(trans) from DCE-MRI showed comparable reproducibility (mean wCV, 5.13% for Gd-DTPA, 8.06% for P792). ICC of K(trans) showed high intra-subject reproducibility (ICC = 0.999/0.995) and inter-subject heterogeneity (ICC = 0.774). Histograms of K(trans) distributions for three measurements had high degrees of overlap (sum of difference of the normalized histograms <0.01). These results represent homogeneous intra-subject measurement and heterogeneous inter-subject character of biological population, suggesting that perfusion MRI could be an imaging biomarker to monitor or predict response of disease.

摘要

动态磁共振生物标志物(基于T2加权或敏感性以及T1加权或弛豫率增强)已被用于评估肿瘤灌注及其对治疗的反应。开发可靠生物标志物的一个重大挑战是对可重复性进行严格评估和优化。本研究的目的是确定使用两种不同分子量(MW)的造影剂(CA):钆喷酸葡胺(Gd-DTPA,0.5 kDa)和钆贝葡胺(P792,6.5 kDa)时,T1加权动态对比增强(DCE)-MRI和T2加权动态磁敏感对比(DSC)-MRI的测量可重复性。每种造影剂均在八只患有皮下MDA-MB-231乳腺异种移植瘤的小鼠身上进行测试。每只小鼠在一周内用DSC-DCE联合方案成像三次,以获得可重复性测量结果。DSC-MRI结果通过对比噪声比(CNR)效率阈值进行评估。正常组织的DSC中出现明显的信号下降(>95%概率阈值),而肿瘤中的信号变化最小或不存在(<95%概率阈值)。钆喷酸葡胺组正常组织中相对血容量(rBV)的平均受试者内变异系数(wCV)为11.78%,钆贝葡胺组为6.64%。钆喷酸葡胺组正常组织中rBV的组内相关系数(ICC)为0.940,钆贝葡胺组为0.978。受试者间相关系数为0.092。DCE-MRI计算得到的Ktrans显示出可比的可重复性(平均wCV,钆喷酸葡胺组为5.13%,钆贝葡胺组为8.06%)。Ktrans的ICC显示出较高的受试者内可重复性(ICC = 0.999/0.995)和受试者间异质性(ICC = 0.774)。三次测量的Ktrans分布直方图有高度重叠(归一化直方图差值之和<0.01)。这些结果代表了生物群体在受试者内测量的同质性和受试者间特征的异质性,表明灌注MRI可能是一种用于监测或预测疾病反应的成像生物标志物。