Prestipino Filippo, Pragliola Claudio, Lusini Mario, Chello Massimo
Department of Cardiovascular Science, Unit of Cardiovascular Surgery, University Campus Bio-Medico of Rome, Rome, Italy.
J Card Surg. 2014 May;29(3):349-50. doi: 10.1111/jocs.12331.
Nickel hypersensitivity is reported in about 10-15% of the general population and manifests mainly with dermatological signs. Chest discomfort, palpitations, signs and symptoms of pericarditis, and migraine are symptoms reported in rare cases of nickel hypersensitivity after implantation of a cardiac device made of nickel. We present the case of a patient with a nickel allergy from an Amplatzer device in which the removal of the device produced resolution of the symptoms.
据报道,普通人群中约10%-15%的人对镍过敏,主要表现为皮肤症状。胸部不适、心悸、心包炎的体征和症状以及偏头痛是植入镍制心脏装置后罕见的镍过敏症状。我们报告了一例因安普特泽装置导致镍过敏的患者,该装置移除后症状得到缓解。