Various sample preparation procedures for the simultaneous determination of As, Sb and Se in fruit juices by hydride generation inductively coupled plasma optical emission spectrometry (HG-ICP-OES) were examined. Applicability of total wet digestion with HNO3/H2O2, partial decomposition (solubilisation in aqua regia), 1:1 dilution with 2% (v/v) HNO3 and direct analysis were evaluated. Hydrides were generated in the reaction of an acidified sample with NaBH4 after pre-reduction with KI-ascorbic acid for total As and Sb, and boiling with HCl for total Se. Best results, i.e. limits of detection (LODs) of 0.51-0.73 ng mL(-1), precision (RSD) within 1.7-3.6% and recoveries for spiked samples between 101% and 106% were found using aqua regia treatment. This procedure simplifying and improving sample preparation step prior to As, Sb and Se measurements in fruit juices by HG-ICP-OES, thus could be adequate for the routine analysis in terms of the quality control of these drinks.
研究了通过氢化物发生电感耦合等离子体发射光谱法(HG-ICP-OES)同时测定果汁中砷、锑和硒的各种样品制备程序。评估了用硝酸/过氧化氢进行全湿消解、部分分解(在王水中溶解)、用2%(v/v)硝酸1:1稀释以及直接分析的适用性。对于总砷和锑,在样品用碘化钾-抗坏血酸预还原后,酸化样品与硼氢化钠反应生成氢化物;对于总硒,样品与盐酸煮沸后生成氢化物。使用王水处理得到了最佳结果,即检测限(LOD)为0.51 - 0.73 ng mL⁻¹,精密度(RSD)在1.7 - 3.6%以内,加标样品的回收率在101%至106%之间。该程序简化并改进了果汁中砷、锑和硒通过HG-ICP-OES测量之前的样品制备步骤,因此在这些饮料的质量控制方面可适用于常规分析。