Rev Sci Instrum. 2014 Apr;85(4):044709. doi: 10.1063/1.4871986.

Abstract

In this paper, the inner surface flash-over of high-voltage self-breakdown switch, which is used as a main switch of pulse modulator, is analyzed in theory by employing the method of distributed element equivalent circuit. Moreover, the field distortion of the switch is simulated by using software. The results of theoretical analysis and simulation by software show that the inner surface flash-over usually starts at the junction points among the stainless steel, insulator, and insulation gas in the switch. A switch with improved structure is designed and fabricated according to the theoretical analysis and simulation results. Several methods to avoid inner surface flash-over are used to improve the structure of switch. In experiment, the inductance of the switch is no more than 100 nH, the working voltage of the switch is about 600 kV, and the output voltage and current of the accelerator is about 500 kV and 50 kA, respectively. And the zero-to-peak rise time of output voltage at matched load is less than 30 ns due to the small inductance of switch. The original switch was broken-down after dozens of experiments, and the improved switch has been worked more than 200 times stably.

摘要

本文采用分布元件等效电路法对用作脉冲调制器主开关的高压自击穿开关内表面闪络进行了理论分析。此外,利用软件对开关的场畸变进行了模拟。理论分析和软件模拟结果表明,内表面闪络通常始于开关中不锈钢、绝缘体和绝缘气体的交界点。根据理论分析和模拟结果设计并制作了一种结构改进的开关。采用了几种避免内表面闪络的方法来改进开关结构。实验中,开关电感不超过100 nH,开关工作电压约为600 kV,加速器输出电压和电流分别约为500 kV和50 kA。由于开关电感小,匹配负载下输出电压从零到峰值的上升时间小于30 ns。原开关在几十次实验后就被击穿,而改进后的开关已稳定工作200多次。

文献AI研究员

20分钟写一篇综述,助力文献阅读效率提升50倍。

立即体验

用中文搜PubMed

大模型驱动的PubMed中文搜索引擎

马上搜索

文档翻译

学术文献翻译模型,支持多种主流文档格式。

立即体验