采用柱后注入内标法结合基质标准化因子,利用液相色谱-电喷雾电离质谱法对各种生物流体中的目标分析物进行定量分析。

Quantification of target analytes in various biofluids using a postcolumn infused-internal standard method combined with matrix normalization factors in liquid chromatography-electrospray ionization mass spectrometry.

机构信息

School of Pharmacy, College of Medicine, National Taiwan University, Taipei, Taiwan.

Department of Oncology, National Taiwan University Hospital, Taipei, Taiwan.

出版信息

J Chromatogr A. 2014 Sep 5;1358:85-92. doi: 10.1016/j.chroma.2014.06.069. Epub 2014 Jun 30.

Abstract

Liquid chromatography-electrospray ionization mass spectrometry (LC-ESI-MS) has become one of the most widely used methods in pharmaceutical laboratories. Although LC-ESI-MS provides high sensitivity and high specificity for quantifying target analytes in complicated biofluids, the associated severe matrix effects (MEs) generally result in large quantification errors. Here, we propose a novel strategy for correcting MEs in various biofluids using a postcolumn infused-internal standard (PCI-IS) method in combination with matrix normalization factors (MNFs). We used the MNFs to normalize the encountered MEs in various biofluids to the MEs encountered in standard solutions. The use of a postcolumn infused-internal standard also corrects the MEs for individual samples. When using the PCI-IS method in combination with MNFs, the calibration curve generated from standard solutions can be applied to quantify the target analytes in various biofluids. We applied this new approach to quantify etoposide and etoposide catechol in plasma and CSF. The accuracy of the test results showed that over 93% of the data have quantification errors less than 20% and that 99% of the data have quantification errors less than 30%. The successful application of this method to evaluate real clinical samples revealed that our proposed MNFs in combination with the PCI-IS method largely simplifies the entire method development and validation processes, saves a great deal of time and cost without sacrificing quantification accuracy, and provides a simple means of quantifying target analytes in various biofluids. This method will be particularly useful in fields in which the same target analytes need to be quantified in various types of matrices, including bioanalysis, forensic toxicology, environmental studies, and food safety control.

摘要

液相色谱-电喷雾电离质谱(LC-ESI-MS)已成为药物实验室中最广泛使用的方法之一。虽然 LC-ESI-MS 为定量复杂生物流体中的目标分析物提供了高灵敏度和高特异性,但相关的严重基质效应(ME)通常会导致较大的定量误差。在这里,我们提出了一种使用柱后注入内标(PCI-IS)方法结合基质归一化因子(MNF)校正各种生物流体中 ME 的新策略。我们使用 MNF 将各种生物流体中遇到的 ME 归一化为标准溶液中遇到的 ME。使用柱后注入内标还可以校正单个样品的 ME。当使用 PCI-IS 方法结合 MNF 时,从标准溶液生成的校准曲线可用于定量各种生物流体中的目标分析物。我们将这种新方法应用于定量血浆和 CSF 中的依托泊苷和依托泊苷儿茶酚。测试结果的准确性表明,超过 93%的数据的定量误差小于 20%,99%的数据的定量误差小于 30%。该方法成功应用于评估真实临床样本表明,我们提出的 MNF 与 PCI-IS 方法相结合,大大简化了整个方法开发和验证过程,在不牺牲定量准确性的情况下节省了大量时间和成本,并为定量各种生物流体中的目标分析物提供了一种简单的方法。该方法将特别有用,在这些领域中需要在各种类型的基质中定量相同的目标分析物,包括生物分析、法医毒理学、环境研究和食品安全控制。

文献AI研究员

20分钟写一篇综述,助力文献阅读效率提升50倍。

立即体验

用中文搜PubMed

大模型驱动的PubMed中文搜索引擎

马上搜索

文档翻译

学术文献翻译模型,支持多种主流文档格式。

立即体验