Guglielmo Flavius F, Mitchell Donald G, Roth Christopher G, Deshmukh Sandeep
Department of Radiology, Thomas Jefferson University, 132 South 10th Street, Philadelphia, PA 19107, USA.
Department of Radiology, Thomas Jefferson University, 132 South 10th Street, Philadelphia, PA 19107, USA.
Magn Reson Imaging Clin N Am. 2014 Aug;22(3):263-82. doi: 10.1016/j.mric.2014.04.004.
This article describes a basic 1.5-T hepatic magnetic resonance (MR) imaging protocol, strategies for optimizing pulse sequences while managing artifacts, the proper timing of postgadolinium 3-dimensional gradient echo sequences, and an effective order of performing pulse sequences with the goal of creating an efficient and high-quality hepatic MR imaging examination. The authors have implemented this general approach on General Electric, Philips, and Siemens clinical scanners.
本文介绍了一种基本的1.5-T肝脏磁共振(MR)成像方案、在处理伪影时优化脉冲序列的策略、钆增强三维梯度回波序列的正确时机,以及为实现高效、高质量肝脏MR成像检查而执行脉冲序列的有效顺序。作者已在通用电气、飞利浦和西门子临床扫描仪上实施了这种通用方法。