Suppr超能文献

肺炎支原体感染的实验室诊断。3. 用改良间接血凝试验检测肺炎支原体IgM抗体。

Laboratory diagnosis of Mycoplasma pneumoniae infection. 3. Detection of IgM antibodies to M. pneumoniae by a modified indirect haemagglutination test.

作者信息

Kok T W, Marmion B P, Varkanis G, Worswick D A, Martin J

机构信息

Division of Medical Virology, Institute of Medical and Veterinary Science, Adelaide, South Australia.

出版信息

Epidemiol Infect. 1989 Dec;103(3):613-23. doi: 10.1017/s0950268800031010.

Abstract

The indirect haemagglutination (IHA) test was compared with the complement-fixation (CF) test for the measurement of antibodies to Mycoplasma pneumoniae. A modification of the IHA was used to measure M. pneumoniae IgM antibodies. Sera were obtained from various groups of patients who were either culture or antigen positive for M. pneumoniae in nasopharyngeal aspirates or who had fourfold or greater increase in CF antibody or a titre greater than or equal to 320. The results of these comparisons showed that the modified IHA test was specific and more sensitive (89% as opposed to 64%) than the CF test. The modified IHA test for the detection of IgM antibody was highly effective in the recognition of recent or current infection with the mycoplasma. It was also of equal sensitivity to an indirect enzyme immunoassay for the detection of IgM antibodies to M. pneumoniae.

摘要

将间接血凝试验(IHA)与补体结合试验(CF)进行比较,以检测肺炎支原体抗体。采用改良的IHA法检测肺炎支原体IgM抗体。血清取自不同组别的患者,这些患者的鼻咽抽吸物中肺炎支原体培养阳性或抗原阳性,或者CF抗体呈四倍或更高倍数升高,或滴度大于或等于320。这些比较结果表明,改良的IHA试验具有特异性,且比CF试验更敏感(分别为89%和64%)。用于检测IgM抗体的改良IHA试验在识别近期或当前支原体感染方面非常有效。它在检测肺炎支原体IgM抗体方面与间接酶免疫测定法具有相同的敏感性。

https://cdn.ncbi.nlm.nih.gov/pmc/blobs/5224/2249550/2e6289ae2b10/epidinfect00018-0205-a.jpg

文献AI研究员

20分钟写一篇综述,助力文献阅读效率提升50倍。

立即体验

用中文搜PubMed

大模型驱动的PubMed中文搜索引擎

马上搜索

文档翻译

学术文献翻译模型,支持多种主流文档格式。

立即体验