Suppr超能文献

使用X线片和双能X线吸收法图像对骨关节炎进行Kellgren-Lawrence分级的可重复性和诊断准确性

Reproducibility and Diagnostic Accuracy of Kellgren-Lawrence Grading for Osteoarthritis Using Radiographs and Dual-Energy X-ray Absorptiometry Images.

作者信息

Yoshida Kanako, Barr Rebecca J, Galea-Soler Sandro, Aspden Richard M, Reid David M, Gregory Jennifer S

机构信息

Musculoskeletal Research Programme, Division of Applied Medicine, Institute of Medical Sciences, University of Aberdeen, Aberdeen, UK.

Medical Imaging Department, Mater Dei Hospital, Msida, Malta.

出版信息

J Clin Densitom. 2015 Apr-Jun;18(2):239-44. doi: 10.1016/j.jocd.2014.08.003. Epub 2014 Oct 8.

Abstract

Advances in image quality from modern dual-energy X-ray absorptiometry (DXA) scanners now allow near radiograph-like quality images at a low radiation dose. This opens potential new applications for the use of DXA scanners to study other musculoskeletal conditions, such as osteoarthritis, which is often investigated by visual assessment of radiographs. Together, osteoporosis and osteoarthritis are the 2 most common musculoskeletal conditions, both of which primarily affect older people. The aim of this study was to determine whether Kellgren-Lawrence grading of DXA images can be used to grade hip osteoarthritis as effectively as radiographs. People who had attended for recent pelvic radiographs underwent DXA of hips (50 hips from 25 people) using a GE Healthcare iDXA scanner. Three observers assigned Kellgren-Lawrence grades to each image, and grading was repeated at least 1 week apart. Intraobserver and interobserver reliability for radiographs and DXA images were calculated using quadratic-weighted kappa (QWK). People were recalled 12 months later, and the tests were repeated with both the radiograph and DXA scans taken within 2 weeks of each other. Hip DXA intraobserver reproducibility achieved a QWK range of 0.88-0.95 and interobserver reproducibility of 0.85-0.88, similar to QWK from hip radiographs. Intraobserver reliability between subject-matched radiograph and iDXA images revealed QWK ranging between 0.80 and 0.88. Reproducibility of hip osteoarthritis grading using DXA was comparable with that of radiographs in this study and similar to repeatability scores previously published in literature. Given the lower radiation dose and the opportunity to simultaneously investigate osteoporosis, DXA presents an attractive imaging option for osteoarthritis.

摘要

现代双能X线吸收测定法(DXA)扫描仪的图像质量进步,现在能以低辐射剂量获取近乎X光片质量的图像。这为利用DXA扫描仪研究其他肌肉骨骼疾病开辟了潜在的新应用,比如骨关节炎,骨关节炎通常通过X光片的视觉评估来进行研究。骨质疏松症和骨关节炎是两种最常见的肌肉骨骼疾病,二者主要影响老年人。本研究的目的是确定DXA图像的凯尔格伦-劳伦斯分级是否能像X光片一样有效地对髋部骨关节炎进行分级。近期接受过骨盆X光检查的人使用通用电气医疗集团的iDXA扫描仪对髋部进行了DXA扫描(来自25人的50个髋部)。三名观察者为每张图像指定凯尔格伦-劳伦斯分级,分级至少间隔1周重复进行。使用二次加权kappa(QWK)计算X光片和DXA图像的观察者内和观察者间可靠性。12个月后召回这些人,并在彼此相隔2周内再次进行X光片和DXA扫描重复测试。髋部DXA观察者内再现性的QWK范围为0.88 - 0.95,观察者间再现性为0.85 - 0.88,与髋部X光片的QWK相似。受试者匹配的X光片和iDXA图像之间的观察者内可靠性显示QWK在0.80至0.88之间。在本研究中,使用DXA对髋部骨关节炎分级的再现性与X光片相当,且与先前文献中发表的重复性评分相似。鉴于较低的辐射剂量以及同时研究骨质疏松症的机会,DXA为骨关节炎提供了一种有吸引力的成像选择。